Télécharger Imprimer la page

Hayward ColorLogic WFCLSYNC Mode D'emploi page 2

Module de synchronisation rvb de lumières del

Publicité

Les langues disponibles

Les langues disponibles

CAUTION: DO NOT USE WITH DIMMERS.
CAUTION: FOR OUTDOOR USE, MOUNT AT LEAST 1 FOOT (30cm) ABOVE GROUND.
WARNING: DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL.
CAUTION: NOT FOR USE WITH SELF-CONTAINED SPAS OR HOT TUBS
Specifications
Length:
4.55 inches (115 mm)
Width:
2.650 inches (67 mm)
Enclosure Type: Painted metal
Electrical:
Input - 14V
Output - 12V
Current – 3A Max
Watts – 36VAC
Frequency – 60Hz
(Use only Hayward provided connection and a maximum length of 100 feet of cord to the waterfall)
NOTE: SUITABLE FOR WET LOCATIONS
Contents
1 - Sync Module (WFCLSYNC)
1 - 3 Way Splitter (WFXSPT3)
1 - User Instruction
Installation
- Sync Module includes a 4 foot long power cable
- Figure 1 shows wiring from Hayward transformer to Sync Module
- Connect and lock the Sync Module from the 3-Way Splitter to the waterfall
power cable(s)
- ColorLogic® light(s) must be connected to the same power source as the
Sync Module.
- The Sync Module is capable of syncing up to 3 LED Waterfalls using the
provided 3 Way Splitter. Multiple Sync Modules can be connected on the
same power source. Consult a qualified professional for electrical work.
NOTE 1: SHALL BE INSTALLED ONLY WITH CSA CERTIFIED
TRANSFORMER (LTBCY11300).
NOTE 2: SHALL BE INSTALLED WITHIN 1 FOOT (30cm) FROM CSA
CERTIFIED TRANSFORMER (LTBCY11300).
AC
DC
Page 2
Figure 1

Publicité

loading