Correction factor for operating pressure changes :
Inlet air pressure
Factor (F1)
Correction factor for ambient temperature changes:
Ambient temperature
Factor (F2)
Correction factor for inlet air temperature changes:
Air temperature
Factor (F3)
Correction factor for DewPoint changes:
DewPoint
Factor (F4)
How to find the air flow capacity:
Air flow
Nominal
Factor
=
X
capacity
duty
(F1)
Example:
An AHT 150 has a nominal duty of 150 scfm
3
(255 m
/h). What is the maximum allowable flow
through the dryer under the following operating
conditions:
Inlet air pressure = 120 psig (8 barg)
−
Ambient temperature = 105° F (40° C)
−
Inlet air temperature = 195° F (90° C)
−
Pressure DewPoint = 45° F (7° C)
−
Each item of data has a corresponding numerical
factor as follows:
Air flow
150
1.07
=
x
capacity
= 137 scfm → This is the maximum flow
rate that the dryer can accept under these
operating conditions.
2.5 CORRECTION FACTORS
psig
60
80
barg
4
5.5
0.79
0.91
ºF
≤ 80
ºC
27
1.22
ºF
140
≤
ºC
60
1.25
ºF
35-40
ºC
1.5-4.9
0.80
Factor
Factor
X
X
(F2)
(F3)
0.94
0.91
x
x
x
100
120
7
8
1.00
1.07
90
100
32
38
1.11
1.00
160
175
70
80
1.14
1.02
41-45
5-7
1.00
How to select a suitable dryer for a given duty:
Minimum
Factor
Design
=
Std. air
X
(F4)
air flow
flow rate
Example:
The procedure here is to list the operating
conditions and then to locate the corresponding
numerical factors:
Design air flow = 95 scfm (161 m
−
Inlet air pressure = 120 psig (8 barg)
−
Ambient temperature = 105° F (40° C)
−
Inlet air temperature = 195° F (90° C)
−
Pressure DewPoint = 45° F (7° C)
−
In order to select the correct dryer model the
required flow rate is to be divided by the correction
factors relating to above mentioned parameters:
Minimum
1.00
=
flow rate
= 104 scfm → Therefore the model suitable
for the conditions above is AHT 150 (150 scfm
or 255 m
140
160
10
11
1.13
1.18
105
110
40
43
0.94
0.89
180
195
82
90
1.00
0.91
46-50
7.1-10
1.08
Factor
Factor
÷
÷
(F1)
(F2)
95
1.07
0.94
÷
÷
3
/h - nominal duty).
GB
180
200
12.5
14
1.23
1.27
115
46
0.83
210
100
0.80
51-54
10.1-12
1.12
Factor
Factor
÷
÷
(F3)
(F4)
3
/h)
0.91
1.00
÷
÷