morse AHT 20 Manuel D'instructions page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operations to be performed by qualified personnel only.
Never work on compressed air system under pressure.
The user is responsible to ensure that the dryer will never be operated with pressure exceeding
the maximum pressure rating on the unit data tag.
Over-pressurizing the dryer could be dangerous for both the operator and the unit.
The air temperature and the flow entering the dryer must comply within the limits stated on the identification
plate. The system connecting piping must be kept free from dust, rust, chips and other impurities, and must
be consistent with the flow-rate of the dryer. In case of treatment of air at particularly high temperature, the
installation of a final refrigerator could result necessary. In order to perform maintenance operations, it
recommended that a dryer by-pass system be installed as shown in the following illustration.
In realising the dryer, particular measures have been taken in order to limit the vibration which could occur
during the operation. Therefore we recommend to use connecting pipes able to insulate the dryer from
possible vibrations originating from the line (flexible hoses, vibration damping fittings, etc.).
CAUTION:
PIPING THE DRYER, INLET/OUTLET CONNECTIONS MUST BE SUPPORTED AS
SHOW IN THE DIAGRAM.
FAILING WILL RESULT IN DAMAGE
2.6 CONNECTION TO THE COMPRESSED AIR SYSTEM
Dryer
AHT 5-12
AHT 18-23
AHT 30-40
AHT 55-60
AHT 80-100
Ø [BSP-F]
A [in - mm]
1/2"
3 1/2" - 90
1"
16 9/16" - 415
1.1/4"
20 11/16 " - 525
1.1/2"
26" - 660
2"
25" - 635