morse AHT 20 Manuel D'instructions page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Only qualified personnel should perform troubleshooting and or maintenance operations.
Prior to performing any maintenance or service, be sure that:
• no part of the machine is powered and that it cannot be connected to the mains supply.
• no part of the machine is under pressure and that it cannot be connected to the compressed
air system.
• Maintenance personnel have read and understand the safety and operation instructions in
this manual.
Recommended maintenance: 1 x per year
ATTENTION! Before maintenance or repair, make sure the BEKOMAT is not pressurised.
ATTENTION! Before installation, maintenance or repair, make sure the BEKOMAT is in a powerless state.
Before work, disconnect from power supply.
MAINTENANCE BEKOMAT
BEKOMAT REPLACEMENT PARTS
Description
Service Unit
Set of seals
5.17 MAINTENANCE BEKOMAT
Remove Control Unit (1) by pressing the snap-fit (2).
Disconnect BEKOMAT from the condensate discharge (3).
Disconnect Service-Unit (4) from condensate inlet.
Check if new Service-Unit (4) is correct and suitable for the
control unit (1) (type description, color of snap-fit).
Reassemble the BEKOMAT with the new Service-Unit (4) in
reverse order.
BEKOMAT 31
AHT 20-100
XE KA31 101
XE KA31 002
GB
BEKOMAT 32
AHT 150-350
XE KA32 101
XE KA32 002

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aht 350

Table des Matières