Connecting the power
,
WARNING:
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Follow all state and local codes or NEC.
The appliance comes with a UL listed 3 wire power
supply cord.
The appliance requires a 3-wire receptacle.
The receptacle must be installed by a licensed
electrician only.
The receptacle must be a 15 A breaker or fuse.
Appliance
BottomFreezer 36"
For the installation position of the receptacle see
"Installation dimensions".
Grounding instruction
This appliance must be grounded. In the event of
a malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of least
resistance for the electric current.
,
WARNING:
Improper connection of the equipment grounding
conductor may result in electric shock. Have the
appliance checked by a qualified electrician or
service technician if you are in doubt as to
whether the appliance has been properly
grounded.
Additional grounding procedure
Some local regulations may require a seperate ground.
In such cases, the required ground wire, clamp and
screw are available as a separate accessory and must
be purchased seperately.
Never ground the appliance to plastic plumbing lines,
gas lines or water pipes.
8
Maximal load at one time
6.0 Ampere
Connecting the water
,
CAUTION:
Only connect the appliance to drinking water!
A cold water connection is required for operation
of the automatic ice maker. The water pressure must
be between 25 and 120 psi. (1.72–8.25 bar).
The installation must comply with local plumbing
regulations.
A separate shut-off valve must be installed for the
appliance water connection.
Do not use a self-piercing valve!
The shut-off valve for the water connection must not be
behind the appliance. It is recommended to place the
shut-off valve directly next to the appliance or in another
easily accessible location.
When installing the water connection, observe the
permitted installation areas for the pipe. For the
permitted installation areas and dimensions see
"Installation dimensions".
The supply pipe can be located at the side on the right
(a), at the side on the left (b) or underneath (c).
Maximum outer diameter of the water pipe
3
(without fittings):
/
" (9.5 mm).
8