APPLIANCE INSTALLATION INSTRUCTIONS.
To limit heating the walls neighbouring the wood burner to 65K (K = degrees Celsius above room temperature), the minimum distances
indicated in the diagram below must be followed.
If the neighbouring walls are made from non-combustible materials that are not damaged by heat ( the wall temperature can reach
200°C), these distances can be reduced to 150 mm.
WOOD BURNER INSTALLATION TOP VIEW
Side wall
600 mm
50cm wide, 50 long, 45mm
thick concrete slab covered by a
reflective plate on the appliance
side (ceramic or stainless steel
type)