Shutdown Instructions; Test Firing The Heater; Storage - Mi-T-M Corporation MH-0060-LM10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

51 to 100 feet long, use 16 AWG rated cord.
101 to 200 feet long, use 14 AWG rated cord.
4. Following the extension cord requirements, plug the extension cord into a 120 volt/60 herts, three hole
grounded outlet.
5. Open gas supply valve slowly.
6. Rotate on/off switch to the ON position. Set thermostat to desired temperature. Thermostat setting may
be too low if heater does not start. Select a highter temperature and start heater.

SHUTDOWN INSTRUCTIONS

To shut off heater:
1. Turn gas valve knob clockwise to OFF position.
2. Turn gas supply OFF by turning LP cylinder valve clockwise to close.
3. Disconnect the power cord.

TEST FIRING THE HEATER

Test fire your construction heater following the lighting instructions applicable to the gas control system
employed.
Leak test all gas connections with 50/50 soap and water solution prior to start-up. Soap bubbles indi-
cate a gas leak. DO NOT use a match or flame to test for gas leaks.
NOTE: Heater surface temperature must be cold before initiating service, cleaning or storage.

STORAGE

Always disconnect the heater from the LP cylinder before putting the heater into storage. If for any
reason the heater is to be stored indoors, the tank MUST be disconnected from the LP cylinder, and the
cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with
the Standard for Storage and Handling of Liquefied Gases, ANSI/NFPA 58 - latest edition. The plastic
valve plug or valve cover supplied with the cylinder must be re-installed on the valve to protect the fitting
from damage.
WARNING: NEVER STORE AN LP CYLINDER INSIDE OF A BUILDING, OR NEAR ANY OTHER GAS
OR OIL BURNING APPLIANCES.
NOTE: Installation and repair of this heater should be done by a qualified service person.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE,
OR WHILE CONNECTED TO A FUEL SOURCE
16
OPERATION
Propane Portable Heaters Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-0150-lm10Mh-0150-lmt0

Table des Matières