Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DISPLAY
DATA
En.SA
Si / no
t.ASE
0.0" ÷ 5.0"
t.rSE
0.0" ÷ 5.0"
P.SEr
0 ÷ 100%
t.PrE
0.5" ÷ 1'.00
dir
dX / SX
P.AP
30 ÷ 100%
P.Ch
30 ÷ 100%
Pr.AP
0 ÷ 70%
Pr.Ch
0 ÷ 70%
SEnS
0.0A ÷ 9.9A
rAAP
0 ÷ 100%
rACh
0 ÷ 100%
St.AP
no
ChiU
PAUS
St.Ch
Stop
APEr
St.PA
no
ChiU
Ch.AU
no
0.5"÷ 15.0'
Ch.tr
no
0.5"÷ 15.0'
PA.tr
no / Si
LUCi
t.LUC
no
CiCL
AUS
tiM
biSt
Mon
SPiA
no
FLSh
W.L.
LP.PA
no / Si

CITY10+ FUNCTION TABLE

DESCRIPTION
ENERGY SAVING function
Anticipation time of the electromagnetic vacuum gripper
Delay time of the electromagnetic vacuum gripper
Power output of the electromagnetic vacuum gripper
Preflashing time
Direction
Motor power in opening phase
Motor power in closing phase
Motor power during opening slow down phase
Motor power during closing slow down phase
Sensitivity
Slow down in opening
Slow down in closing
Start in opening
- The START command was not activated
- the barrier recloses
- the barrier goes into pause
Start in closing
- the barrier finishes the cycle
- the barrier reopens
Start in pause
- The START command is not activated
- the barrier recloses
Automatic reclosing
- Automatic reclosing is not active (corresponds to value 0)
- the barrier recloses after the time set
Closing after the traffic
- Closing after traffic disabled (charge Ch.AU)
- the barrier recloses the set time
Pause after traffic
Courtesy lights
- Timed functioning (from 0 to 20')
- Function disabled
- Turned on for the entire duration of the cycle
Auxiliary channel
- Timed functioning (from 0 a 20')
- Bistable functioning
- Monostable functioning
Setting low voltage exit lights
- Non-utilized
- Flashing function
- Spy lamp function
Flashing indicator in pause
60
DEFAULT
MEMO
Si
0.0"
0.0"
0
1.0"
dX
80
80
25
25
0.0A
25
25
PAUS
StoP
ChiU
no
no
no
CiCL
Mon
FLSh
no

Publicité

Table des Matières
loading

Table des Matières