Start command during the pause
This menu allows establishing the behavior of the control units if a Start
command is received while the barrier is opened in pause.
ChiU
the barrier starts to reclose.
no
the command is ignored.
PAUS
the pause time becomes recharged (Ch.AU)
In order to set up the operations logic "step by step", choose the ChiU
(closing) option.
In order to set up the oprations logic "it always opens", choose the
option no.
ATTENTION: Independently from the option chosen, the Start
command makes the barrier reclose if this has been blocked with
a Stop or if the automatic reclosing is not enabled.

Automatic Closing

In automatic operation, the control unit automatically recloses the
barrier at the end of the preset time.
If enabled from the menu St.PA, the Start command allows closing the
barrier even before the end of a preset time.
In the semi-automatic operation, that is if the function of automatic
closing comes disabled bringing the value to the zero (the display reads
no), the barrier can only be reclosed with the Start command: in this
case the set up of menu St.PA comes ignored.
If during a pause a stop a command is received, the control unit goes
automatically into semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing after the transit through the
barrier, for which usually a lesser time for ChiU. AU (automatic closing)
is used.
The time set for Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after the transit
In order to render minimum the time in which the barrier remains open,
it is possible to make the barrier close as soon as the passage in front
of photocells has ended. If the automatic operation is enabled, the Ch.tr
value is loaded/programmed as time of pause.