Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the barrier starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
Safety ribbon input
This menu allows enabling the input for safety ribbon
no
input disabled (ignored by the control unit).
No jumper with the common is required.
Ch
Input enabled during closure and disabled during opening.
The intervention of the safety ribbon cause the reopening
of the barrier and the disactivation of any automatic closing
Test of the safety ribbons
This menu allows setting the method of control of the safety ribbons
working.
no
Test disabled
Foto
Test enabled for optical safety ribbons
rESi
Test enabled for conductive rubber safety ribbons
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory.
no
Further corrections to carry out: do not quit the programming.
Si
changes complete: when programming is complete and the
data is saved, the display shows the control panel
THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL
UNIT IS READY TO BE USED.
ATTENTION: if exited the menu is done by selecting the
voice command Si the set up data will become lost.
57