5.1- Intended use
- The pump is designed to draw diesel fuel or clear water.
- It must be installed in a dry, clean, ventilated place, protected from weather and excessive heat/cold.
- The maximum suction height should not exceed 6 meters.
- The pump is designed for private household uses such as
- pumping or transferring diesel fuel...
- gardening, irrigation systems, pumping water from tanks...
- The pump must not be used for operations not described in this manual.
It should NOT be used in particular for:
- supllying systems and sprinkling equipment for public gardens,
- continuous operation (for ex.: water circulation,...)
- pumping corrosive liquids, easily flammable, aggressive, explosive or dangerous liquids.
- pumping seawater (salted water), waste water, water containing solids, sand or abrasive particles in
suspension, water containing corrosive substances in general.
- pumping water intended for human consumption or any other food liquid.
- pumping water / liquid having a temperature above 35°C.
NOTE:
- This pump is not intended for cleaning and other pool maintenance operations.
- The pump must not be used in outdoor fountains, garden ponds and similar places.
- The pump is not designed for industrial, artisanal and / or commercial applications (eg, in construction
sites, public parks, sports fields, filling station...).
5.2- Operation
a. If using flexible tubing, attach the ends of the tubing to the tanks. In the presence of an appropriate slot,
solidly grasp the delivery tube before beginning dispensing,
b. Before starting the pump make sure that the delivery valve is closed (dispensing nozzle or line valve).
c. Turn switch on.
d. Open the delivery valve, solidly grasping the end of the tubing.
e. Close the delivery valve to stop dispensing.
f. When dispensing is finished, switch off the pump.
ATTENTION! Functioning with the delivery closed is only allowed for brief periods (2 / 3 minutes
maximum). After use: make sure the pump is turned off.
5.3- Advise for users
IMPORTANT!
- Do not operate the pump without liquid in the pump body: extended operation of the pump when the
discharge valve is closed, can seriously damage the pump.
- In case of prolonged non-use, ensure to switch off the power, and remove plug from socket.
5.4- Lack of Electric power
In case of power failure, it is best to unplug the pump from the power outlet.
A lack of electric power, with the consequent accidental stopping of the pump, can be caused by:
- a safety device tripping
- a drop in line voltage