Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 114
14.3 Call up the secondary
parameters
 Press the Menu button 19 to call up the secondary
parameters.
 Select the desired secondary parameter with the con-
trol knob 13.
9 The parameter code and the corresponding setting
are displayed alternately in the 7-Segment display 20.
 Confirm the secondary parameter by pressing the
Menu button 19.
9 The set value flashes in the 7-segment display 20.
 Use knob 13 to set the desired value.
 Save the set value by pressing the Menu button 19.
‰ Change to the previous or next secondary parameter
with knob 13.
 Exit the secondary parameters by pressing the Elec-
trode/TIG button 18.
The following secondary parameters are available.
Parameter
Start current
Start current
time
Hotstart
Hotstart time
- 28 -
Mode
50 % 5... 200 %
X
0,1 s
0,0... 20 s
X
125 % 5... 200 % X
1,0 s
0,0... 20 s X
909.2779.9-00
Parameter
Arc dynamic
The welding current increases automatically as the
welding voltage is reduced. The arc dynamic indicates
the ratio between the main current and the automatic
increase.
Weld end detec-
tion (correction
value)
Your welding machine switches the welding current off
at a certain arc length. (Weld end detection.) The maxi-
mum length of the arc can be adapted using the „SEE"
parameter.
Tab. 1:
Secondary parameters

14.4 Master-Reset

Warning! All personal settings will be lost.
i
All welding and secondary parameters are
reset to their factory settings (master reset
function).
 Press buttons 18 and 19 simultaneously for at least
3 seconds
9 The 7 segment display and the control panel indica-
tors light up briefly as confirmation.Meldungen
Starting up
Mode
100 % 0... 200 % X
100 % 0... 200 % X
X
09.16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Controlpro micorstick 200 rc

Table des Matières