3. Operation (For Wired Remote controller)
Manual vane angle
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
RETURN SELECT
MENU
OFF
HOLD
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
M-NET address
1
Identify unit Check button
Input display: SELECT
Address
Check
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Select: SELECT
Outlet
Angle
RETURN SELECT
MENU
OFF
HOLD
en
Manual vane angle
Setting
Press the [SELECT/HOLD] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the previous screen when the
transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
unit goes into operation.
Navigating through the screens
• To return to the previous screen ........... [RETURN] button
9
1 Select "Comfort" from the Op-
eration menu, and press the [SE-
LECT/HOLD] button.
ON
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT/HOLD] button.
ON
3 Select the M-NET address for the
units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT/HOLD]
button.
Press the [F4] button to confirm the
unit.
ON
4 The current vane setting will ap-
pear.
Select the desired outlets from "1",
"2", "3", "4", or "1, 2, 3, 4 (all out-
lets)" with the [F1] or [F2] button.
Press the [F3] or [F4] button to go
through the following options and
select the desired setting.
ON
No setting
Step 2
Step 4
Draft
reduction
will be displayed the next time the
Confirmation procedure
Manual vane angle
M-NET address
Identify unit Check button
Input display: SELECT
Address
Manual vane angle
M-NET address
Function setting for unit
with vane fully open.
Return: RETURN
Manual vane angle
No communication
Check Unit state.
Return: RETURN
Step 1
Step 3
Step 5
All outlets
1 Select the "M-NET address" for
the units to whose vanes are to be
1
fixed, with the [F2] or [F3] button.
Press the [F4] button to confirm the
unit.
Check
2 After pressing the [F4] button, wait
approximately 15 seconds, and
1
then check the current state of the
air conditioner.
→ The vane is pointing downward.
→ This air conditioner is displayed
on the remote controller.
→ All outlets are closed. → Press
the [RETURN] button and continue
the operation from the beginning.
→ The messages shown to the left
are displayed. → The target device
does not exist at this refrigerant
address.
• Press the [RETURN] button to
return to the initial screen.
3 Change the "M-NET address" to
the next number.
• Refer to step 1 to change the "M-
NET address" and continue with
the confirmation.