Gorenje Classico DK63CLB Mode D'emploi page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
L2) When the LED is red (motor off) it indicates the FILTER ALARM. When the LED is green (flashing) it indicates that
the TIMER has been activated with the key E.
FILTER ALARM: After 30h of operation, the LED L2 turns RED. It indicates that the grease filters need to be cleaned.
After 120h of operation, the LED L2 turns RED and flashes; It indicates that the grease filters need to be cleaned and
the charcoal filters replaced. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour
counter (RESET) by pressing the key E during display of the filter alarm.
Controls shown in Fig. 14: Button A: turns the lights on/off; every 30 hours of operation the corresponding pilot lamp (S)
comes on to indicate that the grease filters must be cleaned; every 120 hours of operation the corresponding pilot lamp
(S) flashes to indicate that the grease filters must be cleaned and the charcoal filter replaced. To restart the hour counter
(RESET), hold the button A pressed down for about 1" (while the pilot lamp S is on). Button B: drives the motor in first
speed (the corresponding pilot lamp comes on); when holding it down for about 1", the motor cuts out; when pressing the
button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp
flashes). Button C: drives the motor in second speed (the corresponding pilot lamp comes on); when pressing the button
a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes).
Button D: drives the motor in third speed (the corresponding pilot lamp comes on); when pressing the button a second
time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Button
E: drives the motor in fourth speed (the corresponding pilot lamp comes on); when pressing the button a second time
(while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes).
Pay special attention to the grease filters; to remove the filter: push inward on the clamp at the handle and pull the filter
downward. Wash out the filter using a neutral soap. if the model purchased has the controls shown in Figure 13: see the
paragraph "Controls shown in Fig. 13" ("Filter Alarm"). If the model purchased has the controls shown in Figure 11/12: the
grease filter must be cleaned periodically: exactly how often depends on use (at least once every other month). If the
model purchased has the controls shown in Figure 14: the grease filters must be cleaned approximately once every 30
hours of operation (when the light button lamp comes on) - Fig. 14S).
Once the cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1"
(Fig.14A) while the corresponding pilot lamp (S) is on. For further information, see the Controls in Fig.14 in the
paragraph entitled "Operation".
Charcoal filter/s: if using the hood in the filtering hood, the charcoal filter must be replaced periodically. To remove the
charcoal filters, proceed as follows, depending on the model purchased:
- if the hood features round charcoal filters (Fig. 15), remove the charcoal filter by turning clockwise.
- if the hood features a panel type charcoal filter (Fig. 10), remove the charcoal filter by first of all removing the two filter
retainers M.
If the model purchased has the controls shown in Figure 13, see the paragraph "Controls shown in Fig. 13" ("Filter
Alarm"). If the model purchased has the controls shown in Figure 11/12, the charcoal filters must be replaced according
to use: on the average once every 6 months. If the model purchased has the controls shown in Figure14, the charcoal
filters must be replaced each time the light button (Fig.14S) lamp flashes (i.e. every 120 hours of operation).
Lighting:
- To gain access to the bulbs, remove the grease filters as described above and remove the bulbs. Replace only
with CANDLE HALOGEN LAMP - Ø 35mm, E14–220-240 Vac, 28W or INCANDESCENT LAMP-E14–220-240 Vac, 40W
- If the halogen lamps shown in Fig. 16 need changing, slacken the ring nut in an anticlockwise direction and remove the
bulb itself. Replace with the same type of lamp. CAUTION: Do not handle glass bulb with bare hands.
- To change the halogen lamps shown in Fig. 17 open the cover levering from the proper slots. Replace with the same
type of lamp. CAUTION: Do not handle glass bulb with bare hands.
The motor used in this hood features a safety device (thermal cutout) that responds to temperature changes For
accidental reasons or due to installation faults, this device could engage and automatically shut off the motor,
thereby preventing serious damage to the equipment. In such cases, after allowing the motor to cool down, the
hood can be switched on again; the cause of the fault will nonetheless have to be remedied, ensuring installation