1-08413_0715_GA Drumi_Primus_Quantum_Layout 1 13.07.2015 12:00 Seite 14
5.3
Replacing the washer
5.3.1 For reusable cylinders
We recommend replacing the washer in the adapter (art. no. 3056)
for connection to reusable cylinders on a regular basis, in order to rule
out leaking cylinder connections at all times
5.3.2 For disposable cylinders
There is a Longlife washer in the connection socket of the pressure re-
ducer. It is not normally necessary to replace this washer during the
service life of the pressure reducer. The seal can only be replaced using
special tools: Please send in the pressure reducer to Dennerle's Cus-
tomer Service department.
5.4
Cleaning and recalibrating the needle valve
There is a factory-calibrated needle valve in the hose connector of the
pressure reducer.
Should no CO
be supplied although the cylinder is full and the setting
2
knob is turned to fully open position, this indicates that the needle
valve is probably blocked. In this case:
• Open the valve by turning by one half-turn in anti-clockwise di-
rection using a fine screwdriver (blade format 2 – 2.5 x 0.5 mm),
then "flush" with CO
for a few seconds with the setting knob in
2
fully open position.
Important: Do not unscrew valve completely
• Close valve again by one half-turn.
• The valve is factory-set to approx. 120 bubbles per minute when
the setting knob is in fully open position. If necessary, it can be re-
calibrated by carefully screwing it in or out in steps of approx. 1/8
of a turn.
5.5
Removing the CO
2
After prolonged service, the CO
the connector of the pressure reducer and other CO
move the hose, it is best to lever it off using a small screwdriver. Do
not pull the hose off by force or cut it open with a knife, as this may
cause damage to the hose connectors
6 What if ... – Troubleshooting
Fault
Cause
Pressure reducer is skew
A faint hissing sound is
or has not been screwed
to be heard at the scre-
in tight enough.
wed connection bet-
ween pressure reducer
Washer dirty or faulty.
and CO
cylinder.
2
hose
hose may be very firmly attached to
2
equipment. To re-
2
Remedy
Unscrew pressure redu-
cer and screw back in
place without canting.
Fit new washer (see
5.3). Checked that the
washer is fitted cor-
rectly and that the sea-
ling surfaces are clean.
Fault
Cause
CO
cylinder empty
No more bubbles at
2
the CO
diffusor.
2
Setting knob closed
Hose connection leaking
Needle valve blocked
7 Upgrades
Level 1: CO
night cut-off valve: The Dennerle CO
2
cut-off valve Comfort serves to cut off the CO
at night by means of a time switch, as plants do not con-
sume any CO
at night. This saves valuable CO
2
Level 2: Fully automatic: The Dennerle pH Controller Evo-
lution measures the pH value in the aquarium continu-
ously and controls the supply of CO
automatically via the CO
Professional tips from Dennerle
• Large quantities of valuable CO
leaking CO
hoses. We thus recommend the special Softflex CO
2
hose from Dennerle.
• Even when using CO
diffusors with integrated bubble counter, it is
2
nevertheless expedient to install an additional bubble counter close
to the pressure reducer. This enables the number of bubbles to be
set even more simply, quickly and exactly. Recommendation:
Dennerle CO
bubble counter Exact. 10 bubbles per minute
2
correspond to a CO
supply of 1.8 g or 0.9 litres per day.
2

8 Technical data

Maximum permissible cylinder pressure (operating pressure): 160 bar
Connection for hose 4/6 mm
Dynamic Valve Control (DVC) for precision control
Factory-calibrated precision needle valve with stainless steel needle,
adjustable via ultra-fine thread
Self-closing, dynamic pressure-relief safety valve
Remedy
Replace the CO
cylinder
2
Open setting knob
Check hose connection,
replace if necessary
Clean and recalibrate the
needle valve.
night
2
supply
2
.
2
precisely and fully
2
solenoid valve.
2
may be lost every day through
2
2
15