Technical data
Rated data
General electrical data
EMC
Noise emission
Noise immunity
Insulation resistance
Discharge current against PE (to EN 50178)
Enclosure
Protective insulation of control circuits
1)
2.2
Rated data
,
The most important rated data are located on the nameplate of the
device. Additional data can be found in the detailed documentation.
44
Compliance with EN 61800−3
Compliance with limit value class A to EN 55011
(achieved with application−specific collective filter)
Requirements to EN 61800−3
Requirements
1)
ESD
High frequency in cables
RF interference
(enclosure)
Burst
Surge (on mains cable)
Overvoltage category III to VDE 0110
> 3.5 mA AC for operation with corresponding controllers
l
IP20 for standard mounting
IP20 for mounting in cold−plate technique
l
IP20 for mounting in push−through technique; IP54 on the heatsink
l
side
Safe disconnection from supply: Double/reinforced insulation to
EN 50178;
Rated insulation voltage 300 V x √2
Noise immunity in the above−mentioned severities must be guaranteed through the
control cabinet! The user must check the compliance with the severities!
l
Standard
Severity
EN 61000−4−2
3, i. e.
l
8 kV with air discharge
6 kV with contact
l
discharge
EN 61000−4−6
10 V; 0.15 ... 80 MHz
EN 61000−4−3
3, i. e. 10 V/m;
80 ... 1000 MHz
EN 61000−4−4
3/4, i. e. 2 kV/5 kHz
3, i. e. 1.2/50 ms
EN 61000−4−5
1 kV phase−phase
l
2 kV phase PE
l