Electric supply
Nominal power rating
Nominal current
Recommended UPS
Flow rate (∆t=25℃)
Flow rate (∆t=35℃)
Switch on flow rate
Unit dimensions
Package dimensions
Water connections
Working pressure
Nominal pressure
Type of protection
Protection class
Energy efficiency class
This device does not require any maintenance by the user.
Repairs should always be carried out by a licensed contractor.
If faulty, never try to repair the device yourself.
Please contact the nearest service specialist for help.
Care
The housing of the device can simply be cleaned with a damp cloth. Do not use harsh chemicals
or abrasives!
Prolonged shutdown
Do not use heated water as drinking water.
After prolonged shutdown of the device for example after vacation, the device should be fully
heated up to the maximum temperature (tap at minimum flow) before reusing. Pipes should be
flushed for one minute. Check the filter which is incorporated in the cold water inlet of the device
(blue) regularly and keep it free from debris and dirt. This can be accessed by separating the de-
vice from the tap. Make sure you have switched off the main power supply and the main water
supply.
Technical specifications
Model
Unit weight
Cable size
Trend 4500
230 V ~ 50 Hz
4500 W
25 А
30 mА
2.6 l/min
1.8 l/min
1.6 l/min
190 x 157 x 90 mm
1.4 kg
178 x 110 x 220 mm
2
2.5 mm
G 1/2
~0,07 MPa
1 MPa
IP25
I
A
Trend 6000
230 V ~ 50 Hz
6000 W
32 А
3.4 l/min
2.5 l/min
2.2 l/min
190 x 157 x 90 mm
1.4 kg
178 x 110 x 220 mm
2
4 mm
G 1/2
~0,08 MPa
1 MPa
IP25
I
A