Pentair MYERS SP33 Serie Notice D'installation

Pentair MYERS SP33 Serie Notice D'installation

Pompe de puisard submersible

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption
of power to the pump, dirt/debris in the sump, flooding that
exceeds the pump's capacity, electrical or mechanical failure
in the pump, etc.) may prevent your pump from functioning
normally. To prevent possible water damage due to flooding,
consult your dealer about installing a secondary sump
pump, a DC backup sump pump, and/or a high water alarm.
See "Troubleshooting" in this manual for information about
common sump pump problems and remedies.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm.
MOTOR, SWITCh, & CORd SPECIFICATIONS
Model Number
Motor hP
SP33T1
1/3
SP33V1
1/3
SP55T1
1/2
SP55V1
1/2
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM
PH: 888-987-8677
© 2014 Pentair Ltd. All Rights Reserved.
Individual Branch Circuit Required
Max. Load Amps
9.0
9.0
5.5
5.5
InstallatIon, operatIon, & parts Manual
SP33 and SP55 Series
Submersible Sump Pumps
1.
Know the pump application, limitations, and potential
hazards.
2.
Disconnect power before servicing.
3.
Release all pressure within system before servicing any
component.
4.
Drain all water from system before servicing.
5.
Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
6.
Check hoses for weak or worn condition before each
use, making certain that all connections are secure.
7.
Periodically inspect sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
8.
Provide means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
9.
Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master
switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
11. This equipment is only for use on 115 volt and is
equipped with an approved 3-conductor cord and
3-prong, grounding-type plug.
To reduce risk of electric shock, pull
plug before servicing. This pump has not been
investigated for use in swimming pool areas. Pump
is supplied with a grounding conductor and
grounding-type attachment plug. Be sure it is
connected only to a properly grounded grounding-
type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.
(Amps)
Cord Length
15
15
15
15
Switch Setting
inches (mm)
On
8'
13" (330)
6" (152)
8'
8-1/2" (216)
4" (102)
8'
13" (330)
6" (152)
8'
8-1/2" (216)
4" (102)
MY503 (04/02/14)
Off

Publicité

Table des Matières
loading

Sommaire des Matières pour Pentair MYERS SP33 Serie

  • Page 1 Cord Length SP33T1 13" (330) 6" (152) SP33V1 8-1/2" (216) 4" (102) SP55T1 13" (330) 6" (152) SP55V1 8-1/2" (216) 4" (102) 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 MY503 (04/02/14) © 2014 Pentair Ltd. All Rights Reserved.
  • Page 2 INSTALLATION 12. A ground fault circuit is recommended for use with any electrical appliance submerged in water. Installation and Install pump in sump pit with minimum diameter of 10" all wiring should be performed by a qualified electrician. (254mm). Sump depth should be 10" (254mm). Construct 13.
  • Page 3 ELECTRICAL hazardous Voltage. Can cause severe or fatal electric shock. Pump is supplied with a grounding conductor and ground ding-type attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly grounded, grounding type receptacle. Ground 3.5"...
  • Page 4: Replacement Parts List

    REPLACEMENT PARTS LIST Model Impeller SP33T1 PS5-271P SP55T1 RP0000911A SP33V1 PS5-271P SP55V1 RP0000911A SP33T1 SP33V1 description Qty. SP55T1 SP55V1 Power Cord Assembly PS117-54-TSU Tethered Float Switch Assembly FP18-15BD – Vertical Float Switch Assembly FPS17-66 Screw, #8-32x7/8” Hex Head Motor Volute (Upper) PS1-31P Screw, #8-32x5/8”...
  • Page 5: Troubleshooting Chart

    TROuBLEShOOTING ChART SYMPTOM PROBABLE CAuSE(S) CORRECTIVE ACTION Pump won’t start or run. Blown fuse. If blown, replace with fuse of proper size. Low line voltage. If voltage under recommended minimum, check size of wiring from main switch on property. If OK, contact power company or hydro authority. Defective motor.
  • Page 6 Limited Warranty Myers ® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Jet pumps, small centrifugal pumps, submersible pumps and 12 months from date of original installation, related accessories...
  • Page 8: De Fonctionnement Et Des Pièces Série Sp33 & Sp55 Pompe De Puisard Submersible

    8-1/2 po (216) 4 po (102) SP55T1 8 pi 13 po (330) 6 po (152) SP55V1 8 pi 8-1/2 po (216) 4 po (102) 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 MY503 (04/02/14) © 2014 Pentair Ltd. All Rights Reserved.
  • Page 9: Caractéristiques

    INSTALLATION 12. Il est recommandé d’utiliser un disjoncteur de fuite à la terre avec tous les appareils électriques immergés dans l’eau. Toute Installer la pompe dans un puisard ayant un diamètre et une l’installation et tout le câblage doivent être effectués par un profondeur minimum de 254 mm (10 pouces).
  • Page 10: Électricité

    ÉLECTRICITÉ Tension dangereuse. Risque de secousses électriques graves, voire mortelles. La pompe est livrée avec un conducteur et une fiche de mise à la terre. Pour réduire les risques de secousses électriques, brancher cette pompe dans une prise de courant à trois trous adéquatement mis à la terre. La broche de la 8,9 cm fiche du cordon est prévue à...
  • Page 11: Liste Des Pièces De Rechange

    LISTE dES PIÈCES dE REChANGE Modèle Impulseur SP33T1 PS5-271P SP55T1 RP0000911A SP33V1 PS5-271P SP55V1 RP0000911A SP33T1 SP33V1 Réf. désignation Qté SP55T1 SP55V1 Ensemble de cordon d'alimentation PS117-54-TSU Attache du cordon de l’interrupteur flotteur FP18-15BD – Ensemble d’interrupteur à flotteur vertical FPS17-66 Vis, No 8-32 x 7/8 po à...
  • Page 12 TABLEAu dE dIAGNOSTIC dES PANNES INCIdENTS CAuSES POSSIBLES REMÈdES La pompe ne démarre pas Fusible sauté. Le remplacer par un fusible de calibre adéquat. ou ne fonctionne pas. Tension de ligne basse. Si la tension est inférieure à la tension minimale recommandée, vérifier le calibre du câblage côté...
  • Page 13: Garantie Limitée

    Garantie Limitée Myers® garantit à l’acheteur-utilisateur initial (« l’acheteur » ou « vous ») des produits figurant ci-dessous qu’ils seront exempts de tout défaut de matériel et de fabrication pour la période de garantie indiquée ci-dessous. Produit Période de garantie du produit selon la première éventualité...
  • Page 15: Información Sobre La Seguridad

    Encendido Apagado SP33T1 13" (330) 6" (152) SP33V1 8-1/2" (216) 4" (102) SP55T1 13" (330) 6" (152) SP55V1 8-1/2" (216) 4" (102) 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 MY503 (04/02/14) © 2014 Pentair Ltd. All Rights Reserved.
  • Page 16 INSTALACIÓN 12. Se recomienda utilizar un disyuntor de escape a tierra con todo aparato eléctrico sumergido en agua. La instalación y todo el Instale la bomba en el foso del sumidero con un diámetro cableado deben ser realizados por un electricista competente. mínimo de 10"...
  • Page 17 INFORMACIÓN ELÉCTRICA Tensión peligrosa. Existe el riesgo de choques eléctricos graves o fatales. La bomba viene equipada con un conductor de puesta a tierra y un enchufe de conexión de tipo puesta a tierra. Para reducir el riesgo de choque eléctrico, asegúrese de que esté...
  • Page 18: Lista De Repuestos

    LISTA dE REPuESTOS Modelo Impulsor SP33T1 PS5-271P SP55T1 RP0000911A SP33V1 PS5-271P SP55V1 RP0000911A SP33T1 SP33V1 Clave descripción Cant. SP55T1 SP55V1 Unidad del cordón eléctrico PS117-54-TSU Abrazadera del cordón del interruptor de flotador anclado FP18-15BD – Unidad del interruptor de flotador vertical FPS17-66 Tornillo, cabeza hexagonal #8-32x7/8”...
  • Page 19 TABLA dE LOCALIZACIÓN dE FALLAS SÍNTOMA CAuSA(S) PROBABLE(S) ACCIÓN CORRECTIVA La bomba no arranca o no Fusible quemado. Si está quemado, cámbielo por un fusible del tamaño adecuado. marcha. Línea de baja tensión. Si la tensión se encuentra por debajo del mínimo recomendado, verifique el tamaño de los cables desde el conmutador principal en la propiedad.
  • Page 20: Garantía Limitada

    Garantía Limitada Myers le garantiza al consumidor inicial (“Comprador” o “Usted”) de los productos indicados a continuación, que éstos estarán libres de defectos en materiales y en mano de obra durante el Período de Garantía especificado a continuación. Producto Período de garantía lo que ocurra primero: Bombas de chorro, pequeñas bombas centrífugas, bombas 12 meses desde la fecha de la instalación inicial, o...