Pentair MYERS SP33 Serie Notice D'installation page 3

Pompe de puisard submersible
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL
hazardous Voltage. Can cause severe or
fatal electric shock. Pump is supplied with a grounding
conductor and ground ding-type attachment plug. To reduce
risk of electric shock, be certain that it is connected only to a
properly grounded, grounding type receptacle. Ground
terminal on pump cord plug is provided for your protection.
DO NOT REMOVE!
A ground fault circuit interrupter is recommended for use with
any electrical appliance submerged in water. For installation
of such a circuit, consult a licensed electrician.
OPERATION / MAINTENANCE
Risk of electric shock. Before attempting to
check why unit has stopped operating, disconnect power
from unit. do not handle pump with wet hands or when
standing on wet or damp surfaces, or in water.
Risk of flooding. If a flexible discharge hose
is used, pump may move when motor starts. If the switch hits
the side of the sump, the switch may stick and prevent the
pump from starting. Make sure the pump is secured so it
cannot move around in sump.
Risk of sudden starts. The pump motor is
equipped with automatic resetting thermal protector and
may restart unexpectedly.
1.
If protector trips, motor may be overloading. Check for
the following problems:
a.
Not enough back pressure in discharge pipe.
b.
Voltage too high or too low.
c.
Wires to motor too small.
d.
Motor incorrectly connected to power supply wires.
e.
Defective motor.
2.
Shaft seal depends on water for lubrication and cooling.
Do not operate pump unless it is submerged in water as
seal may be damaged if allowed to run dry.
3.
Motor is equipped with automatic reset thermal
protector. If temperature in motor should rise unduly,
switch will cut off all power before damage can be done
to motor. When motor has cooled sufficiently, switch will
reset automatically and restart motor. If protector trips
repeatedly, unplug the pump and remove it; check for
cause of difficulty. Low voltage, long extension cords,
clogged impeller, very low head or lift, etc., could cause
cycling.
4.
Pump will not remove all water. If manually operated
pump is operating and suddenly no water comes out
discharge hose, shut off unit immediately. Water level is
probably very low and unit has broken prime.
CLEANING ANd REPLACING
IMPELLER
1.
Unplug the pump.
2.
Remove pump from sump pit.
3.
Turn the pump upside down and remove the screws
securing the lower volute.
4.
Hold the motor shaft with a screwdriver in the slot on the
bottom end of the shaft, and unscrew the impeller off of the
shaft.
5.
Clean and replace the impeller as necessary.
6.
Reverse Steps 1 through 5 above to replace the impeller
and reinstall the pump.
7.
Fill the sump with water and run the pump through
one complete cycle to make sure that it is correctly
reassembled and operating as it should.
3.5"
(89 mm)
Float Switch Tether Length
VERTICAL FLOAT SWITCh -
INSTALLATION
1.
Assemble by placing switch on post located on top of
pump. As shown in Figure A.
2.
Install screw.
3.
Plug piggyback switch cord into 115V AC outlet. Then,
plug pump into piggyback switch cord. Do not allow cord
to interfere with float control motion or to drape over pump
motor. With electrician's tape or cable ties secure cord to
discharge pipe for cord protection.
Figure A
FLOAT SWITCh -
OPERATIONAL ChECK
1.
Fill the sump with correct amount of water to check
operation and tightness of connections. During the first
cycle, it may take 30 seconds or more before pump is
primed and pumping. Pump will start as indicated in the
"Motor, Switch and Cord" Specifications Table, Page 1.
2.
Check turn-off position. Pump will stop approximately as
indicated in the "Motor, Switch and Cord" Specifications
Table, Page 1.
3.
If pump does not operate check electrical service.
NOTICE: Float switch tether length is set at factory. It is 3.5"
(89mm) for SP Series pumps. Do not change tether length
of float switch. Float must swing through its complete arc
without interference.
3
030 0893

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Myers sp55 serie

Table des Matières