1.2. Problems in the temperature sensor module
The receiver receives signals from sensors, but fails to registrate
signals from one sensor in particular.
Potential problems:
-
Batteries are missing or are at a low charging level
-
Reversed polarity of the sensor's batteries
-
The sensor's location is outside of the receiver's reception
range
-
Damage to the sensor (by corroded battery contacts, moisture
or battery leakage)
E
-
Problems in the radio signal communication
N
Suggested solutions:
G
-
Insert fully charged batteries in the sensor and repeat the
L
communication test (please check the polarisation of the
batteries before inserting!!)
I
-
Check the battery contacts and remove all corrosion and
moisture effects.
S
H
Type:
Radio:
USB:
Supply:
RTC battery:
SD card:
Internal memory: 2MB data-flash (about 9 days for
Software:
Extra information and possible updates can be found on www.arexx.com
Further questions can also be put on our forum, see www.arexx.com
Technical details
BS750-SD
ISM 433MHz, Multilogger RF-protocol.
USB 2.0, Multilogger USB-protocol.
– 7.5V DC / 100mA
CR2032 3V
micro SD (SD, SDHC)
10 sensors, 18 days for 5 sensors, etc.)
http://www.arexx.com