TABLE 2: INSTALLATION DIMENSIONS FOR CVS30R/ 36R/ 45R WITH THERMA-
DOR COOKTOP
Cooktop
Model No.
30" Cooktops: Installed with UCV30
SGS304*
SGSX304*
CET304
CEP304
CEM304
36"Cooktops: Installed with UCV36
SGS365**
SGSX365**
CET365
CEP365
CEM365
45" Cooktops: Installed with UCV45
SGS456
SGSX456
CET456
CEP456
CEM456
Table 2 Notes
* Dimension "SB" is the minimum distance from the leading
edge of the counter to the leading edge of the cutout.
++Dimension "BT" is the thickness of backsplash that
provides 1/4" clearance between vent and backsplash.
Any backsplash with a curved radius where it meets the
counter will require additional clearance. Thicker
backsplashes may be used by increasing the counter
and cabinet depths.
INSTALLATION WITH THERMADOR COOKTOPS WHEN SPECIFIED
Figure 7
CW
CD
Cutout
Cutout
Width
Depth
28-15/16
22-1/4
28-15/16
22-1/4
28-3/4
22-1/8
28-3/4
22-1/8
28-3/4
22-1/8
34-15/16
22-1/4
34-15/16
22-1/4
34-3/4
22-1/8
34-3/4
22-1/8
34-3/4
22-1/8
43-15/16
22-1/4
43-15/16
22-1/4
43-3/4
22-1/8
43-3/4
22-1/8
43-3/4
22-1/8
OW
OD
Overall
Overall
Width
Depth
31
23-3/4
31
23-3/4
31
23-7/8
31
23-7/8
31
23-7/8
37
23-3/4
37
23-3/4
37
23-7/8
37
23-7/8
37
23-7/8
46
23-3/4
46
23-3/4
46
23-7/8
46
23-7/8
46
23-7/8
All dimensions are in inches and are based upon a
standard 24" deep base cabinet with 25" countertop.
* * SGC and SGCS: width in table is at the widest point
(center).
Refer to cooktop Installation Instructions for complete
information prior to making any cutouts.
Clearance is provided to allow raising of the hinged main
top.
Page 7
SB
BT, Max++
Minimum
Backsplash
Set Back
Thickness
1-1/2
1-1/2
2-1/2
2-1/2
2-1/2
1-1/2
1-1/2
2-1/2
2-1/2
2-1/2
1-1/2
1-1/2
2-1/2
2-1/2
2-1/2
2 1/4"
3/4
3/4
0
0
0
3/4
3/4
0
0
0
3/4
3/4
0
0
0