The unit must be earthed using sockets with contact to earth. The manufacturer declines all responsibility in the event of
failure to follow this safety measure. If the unit has to be installed at a distance from the electric power sockets, the
connection must be made according to the Standards in force. It is absolutely forbidden to use adapter plugs. The
manufacturer declines all responsibility for injury to people or damage to objects caused as a result of improper
installation.
6 – Technical characteristics
The unit is supplied together with a plastic bag containing this instruction manual that must be retained. The manual
contains technical details, electrical diagrams and tables regarding the unit.
The technical details of the unit are also provided on the serial number plate (FIG. 9 page 4) which specifies:
1. Name and address of the manufacturer
2. Commercial name of the cabinet
3. Cabinet code
4. Cabinet serial number
5. Rating
6. Frequency
7. Max absorbed current
8. Max absorbed power
9. Max absorbed power during defrosting
10. Standard lighting power
11. Net display area
12. Type of cooling gas used
13. Weight of cooling gas loaded in each unit
14. Climatic class and reference temperature (dry bulb)
15. Electrical safety factor
16. Work schedule number
17. Work order number
18. Year of manufacture
19. Heating capacity
20. QR code
21. EAC marking
Warning: Neither the registration plate nor the warning labels must be removed under any circumstance. The
manufacturer declines all responsibility if this warning is not followed.
It is declared that the equipment complies with the Decree Law 25/01/1992 N. 108 in accordance with CE Directive
89/109 concerning materials and objects destined to come into contact with foodstuffs.
7 – Filling with products and use of the cabinet (startup)
If the island has been set at a sharp angle during positioning, wait at least three hours before starting it up to allow the
lubricating oil to collect in the compressor. If this instruction is not followed the motor-driven condenser may be damaged
beyond repair. Any swelling of the unit while working does not compromise its proper functioning.
The island may only be started up for the first time when points 3 and 4 have been completed.
With the island turned off, proceed as follows: remove the protective plastic film on the outside and then clean the unit,
following the instructions given in point 10.
Fit the plug in the socket (with the characteristics described in point 5) and operate any remote-control switch that may
have been fitted. A slight operating noise made by the motor and the display turned on indicate that the unit has been
switched on.
The display (page 4, FIG. 10) located on the front panel indicates the operating temperature of the island. The instruction
booklet of the electronic controls, to which the display refers, is enclosed with the instruction manual (this device cannot
be tampered with due to a safety password that only a specialized technician can change).
The unit starts its cooling cycle after it has been switched on. The product can be loaded when the temperature shown on
the display is -18°C for frozen packed foods and -20°C for ice cream.
The unit has been designed to display packed foodstuffs, it must maintain the temperature of the product and must not
lower it, and consequently, the product must only be placed inside the unit if it is already refrigerated and is at its
respective preservation temperature.
Bottles and glass containers or jars full of liquid must not be stored in the BT versions as they may burst.
For a correct preservation of the product, it is advisable:
-
Never exceed the maximum load line shown on the inside of the island (page 4, FIG. 11):
- Urano: maximum load line = 55 cm by climatic class 3 (25°C RH 60%)
- Gaia: maximum load line = 50 cm by climatic class 3 (25°C RH 60%)
-
When an island that is already partially loaded with goods is filled with more products (apart from adhering to the
points referred to above), it is good practice to place the new foodstuffs under the existing ones.
-
Each unit is equipped with sliding covers in low-emissivity glass. These are necessary for the proper working, they
must be kept closed (page 4, FIG. 12) and they can be opened only to fill up and take out the products.
The plug-in islands are provided, as a standard fitting, with an electronic control. The thermostat adjustment and the
amount of gas are set in the factory and any tampering with these settings will relieve the manufacturer of all
responsibility.
18