Replacement Parts and Accessories

Description
3M™ Accuspray™ Fluid Needle
3M™ Accuspray™ Air Flow Control Valve
3M™ Accuspray™ Atomizing Head Refill Kit, 1.8 mm
3M™ Accuspray™ Atomizing Head Refill Kit, 1.4 mm
3M™ Accuspray™ Atomizing Head Refill Kit, 2.0mm

Troubleshooting

Problem
Poor Spray Pattern
Heavy Middle Pattern
Intermittent Pulsating Spray Low fluid in cup
Insufficient / No Paint Flow
Overspray is Excessive
Coating Leak
Cause
Air cap or fluid tip clogged
Bent fluid needle
Not enough atomizing pressure. Increase atomizing pressure.
Too much fluid flowing from
PPS cup.
Clogged fluid tip
Loss of air pressure
Empty 3M™ PPS™ cup
Clogged air passage
Gun too far from target
Too much atomizing air for
coating being sprayed
Damaged/worn atomizing head
Fluid needle not closing
12
Replacement PN
16571
16573
16611
16612
16609
Remedy
Replace atomizing head
Replace fluid needle
Reduce fluid flow by turning fluid
adjustment knob clockwise (CW)
Add fluid
Replace atomizing head
Check air source
Add fluid
Replace atomizing head
6-8 inches (150-200 mm) is ideal
Reduce atomizing air
Replace atomizing head
Ensure fluid needle spring is in place
Clean fluid needle with
appropriate solvent