Keep the upper metal rails handy. Proceed as described above. Now attach the upper rails to the lower rails.
Please note: The piping may not rest on the hood and has to be suspended as well.
6. General information
Due to the regulations of the German health and safety agency, companies are obligated to minimize hazardous substances in the working
area.
It is necessary to maintain the filter unit at least once a year by qualified staff. If the system is used non stop, the unit has to be maintained every
2000 operating hours. According to the operating safety regulations, a qualified person is a person, which has obtained the required expert
knowledge in testing the work equipment by professional training and (recent) work experience.
Only regular maintenance guarantees that your extraction hood stays in good condition.
Non adherence to the instructions in this user manual can result in loosing the guarantee.
The welding and cutting fume has to be disposed according to the local regulation.