USE LIMITS
Up-and-over
Sectional
non slide-away
900HA7 with 3 m guide
H max = 2.6m
H max = 3m
S max=10m²
S max=9m²
900HA7 with 4 m guide
H max = 3.6m
H max = 3.4m
S max=11m²
S max=10m²
2.4 - Technical specifications
Recommended model and use - Available guide and dimensions
MODEL
MATERIAL
900RAL30
Aluminium
900RAL40
Aluminium
900RAB3X1
Steel
900RAB3
Steel
900RAB4
Steel
900RA3X1
Steel
900RA3
Steel
The data shown may vary according to the sliding and balancing performance of the door and the type of guide used.
WITH RAL30
235
WITH OTHER
GUIDES
235
2.5 - List of cables required
In a typical plant, the cables necessary for connection of the various
devices are shown in the cable list table. The cables used must be
suitable for the type of installation, for example we recommend a
CABLE LIST TABLE
CONNECTION
Power supply line
Flashing light, courtesy light, ambient light sensor
Antenna
Transmitter photocells
Receiver photocells
Radio sensitive edge (*)
Key selector
If there is not a suitable power outlet near the equipment, contact
qualified personnel for its installation.
Up-and-over
slide-away
H max = 2.4m
S max=9m²
H max = 3.4m
S max=10m²
NOTES
With integrated LED lighting
With integrated LED lighting
330
3065
114
330
2914
70,5
USE LIMITS
Up-and-over
Sectional
non slide-away
900HA10, 900HA10E, 900HA10L with 3 m guide
H max = 2.6m
H max = 3m
S max=13m²
S max=13m²
900HA10, 900HA10E, 900HA10L with 4 m guide
H max = 3.6m
H max = 3.4m
S max=16m²
S max=14m²
DRIVE TYPE
TOTAL LENGTH
Belt
3090 mm (1x3m)
Belt
4090 mm (1x4m)
Belt
2940 mm (3x0.98m) 2510 mm
Belt
2940 mm (1x2.9m)
Belt
3940 mm (1x3.9m)
Chain
2940 mm (3x0.98m)
Chain
2940 mm (1x2.9m)
84
84
H03VV-F type cable for indoor installation or H07RN-F for outdoor
installation.
CABLE TYPE
Schuko CEE 7/4
4 x 0.5 mm
2
1 x RG58 type cable
1 x cable 2 x 0.5 mm
2
1 x cable 4 x 0.5 mm
2
1 x cable 4 x 0.5 mm
2
1 x cable 2 x 0.5 mm
2
(*): refer to the manufacturer's instructions
Up-and-over
slide-away
H max = 2.4m
S max=13m²
H max = 3.4m
S max=14m²
OF GUIDE
TRAVEL
2660 mm
3660 mm
2510 mm
3510 mm
2510 mm
2510 mm
31
28
MAX LENGTH
PERMITTED
20 m
20 m (recommended < 5 m)
20 m
20 m
<2 m
20 m
EN