• You can press the Menu Button and then select Silent Mode in Normal Charging to
mute the charging station. In this mode, the charging current and the fan speed will be
reduced. Note that there will be no sound prompt since the buzzer is turned off.
• If the power is insufficient during charging, the Battery Station will temporarily stop
supplying power to the remote controller port to ensure the batteries charge.
Discharging
Connected to a AC Power
1. Insert the TB50 Intelligent Battery into the Battery Port.
2. Press the Power Button to turn on the Battery Station.
3. Toggle the Status Switch to the right to enter the discharging status.
4. Toggle the Option Switch to discharge the power level to about 25% or 50%, then press the
Confirm Button to start discharging.
Disconnected from a AC Power
1. Insert the TB50 Intelligent Battery into the Battery Port.
2. Toggle the Status Switch to the right to enter the discharging status.
3. Toggle the Option Switch to select to discharge the power level to about 25% or 50%.
4. Press Menu Button > Power Button > Confirm Button in sequence quickly to turn on the
Battery Station and start discharging.
• Select appropriate discharging power level to meet your needs.
25%: This power level is suitable for safe transportation.
50%: This power level is suitable for safe long-term storage.
• All batteries can be discharged at the same time in discharging
status, as soon as inserted into the battery port.
• The discharging process may produce excess heat, please stay away from the air vent to
avoid scalding.
• DO NOT close the battery station during discharging and ensure it is both well ventilated
and able to dissipate heat, to avoid high temperature in the battery station.
• If the battery station is not connected to a AC power when discharging, only USB port can
be used to charge the mobile device, and the remote controller port is not available.
Display Screen
The Display Screen will show each battery's current power level, charging voltage, current,
temperature, remaining charging time and error messages when charging/discharging. If the
temperature is not appropriate for charging, the battery will heat itself automatically or cool to an
appropriate temperature and start charging.
©
2017 DJI All Rights Reserved.
5
CHARGING
39%
40%
22.9V
23.0V
0.0A
0.0A
49
C
3
C
Cooling
Heating
94%
95%
25.7V
25.9V
2.9A
2.5A
34.2
C
33.8
C
15min
13min
80%
25.1V
C2
0.0A
28.9
C
47min
30%
31%
21.2V
21.2V
6.6A
6.6A
29.9
C
29.7
C
47min
43min
OPTION
25%
50%