Installation; Mounting Of Metal And Polycarbonate Housing - E+E Elektronik EE23 Serie Manuel D'utilisation

Masquer les pouces Voir aussi pour EE23 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

all dimensions in mm (")
metal housing
polycarbonate
housing

INSTALLATION

Mounting of metal and polycarbonate housing

1. Drill the mounting holes according to the mounting template.
For the polycarbonate housing a special mounting set for
installation onto mounting rails is available (refer to "Accessories").
2. The bottom part of the housing is mounted with 4 screws (screw
diameter: < 4.2mm
3. Connection of the transmitter (refer to "electrical connection")
4. Mounting of the middle part and cover with 4 screws (included in
the scope of supply)
Model A (wall mounting)
For mounting template for metal and polycarbonate housing see above.
Transmitter EE23-xAx series are designed for wall mounting.
working range sensor probe:
working range electronics:
The sensor probe must point downwards.
Model B (duct mounting)
For mounting template for metal and polycarbonate housing see above.
Positioning of bore holes top left to center line of the probe:
metal housing:
x = 28.5mm
polycarbonate housing: x = 20.5mm
Transmitter EE23-xAx series are designed for duct mounting.
working range sensor probe:
working range electronics:
The sensor probe must point horizontal or downwards in the duct
channel.
17
; not included in the scope of supply).
(0.2")
-40...60°C
-40...60°C
y = 37.5mm
(1.1")
y = 25.4mm
(0.8")
-40...80°C
-40...60°C
(-40...140°F)
(-40...140°F)
(1.5")
(1")
(-40...176°F)
(-40...140°F)

Publicité

Table des Matières
loading

Table des Matières