Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
Blue
Brown
If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
'E' or with the symbol (
coloured green or green and yellow.
2. Connect the blue (Neutral) wire to the
terminal in the plug marked 'N' or
coloured black.
3. Connect the brown (Live) wire to the
terminal marked 'L', or coloured red.
The extractor hood should only be
connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
above the chimney panelling in the ceiling.
Electrical data:
Are to be found on the name plate inside
the appliance after removal of the filter
frame.
Before undertaking any repairs,
always disconnect the extractor hood from
the electricity supply.
Length of the connecting cable: 1.30 m.
– Earth
– Neutral
– Live
), or
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified
person in order to prevent serious injury to
the user.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
Installation
The extractor hood is designed to be
fitted to the kitchen ceiling or a rigid
suspended ceiling.
Ensure that the minimum distance
between hotplate and extractor hood is
550 mm for electric hotplates and 650 mm
(LC 97050: 750 mm) for gas hotplates.
1. Mark the centre point of the extractor
hood on the ceiling.
2. Using the template, mark screw
positions on the ceiling. Fig. 5.
3. Drill the 8 mm l fixing holes and insert
the wall plugs into the holes. Fig. 5.
4. Screw on the support frame. Fig. 5.
11