Electrical Connections; Risk Of Injury - Siemens LC958BB90/03 Mode D'emploi Et Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
E
LECTRICAL CONNECTION
Before connecting the appliance to the
power supply, always follow the instructions
and warnings in the chapter entitled "Safety
instructions"!
The extractor hood may only be connected
by a qualified electrician who is familiar with
the regulations of the relevant electricity
supply company.

RISK OF INJURY

If the power cord of the extractor hood is
damaged, it must be replaced by the
manufacturer, his customer service or a
similarly qualified person to prevent hazardous
situations.
The extractor hood may be connected to a
correctly installed earthed socket only.
Attach the earthed socket as directly as
possible behind the flue duct.
– The earthed socket should be connected via
its own circuit.
– If the earthed socket is no longer accessible
following installation of the extractor hood,
a disconnector must be fitted as for a
permanent connection.
Installation instructions
If a permanent connection is required
A disconnector must be provided on the
installation side. Switches with a contact
opening of more than 3 mm and all-pole
disconnection are regarded as disconnectors.
This includes LS switches, fuses and contactors.
Electrical specifications
The required connection data can be found on
the rating plate inside the appliance when the
grease filters have been removed.
Length of the power cord: approx. 1.30 m.
This extractor hood complies with the EC
interference suppression regulations.
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lc968ba90Lc258ba90Lc958bb90/01

Table des Matières