Normal Operation—E-P Plus,
M-Style Washer-Extractor
Add chemicals, if required.
depending on the optional hardware furnished and the formulas used. The possible methods are as
follows:
=Automatically inject chemicals with a pumped chemical or central liquid supply system.
=Load the supply injector before starting the cycle. Supplies are flushed in automatically.
=Re-load supply injector compartments or manually flush compartment one during the cycle,
when prompted by the formula.
=Pour supplies through the soap chute before or during the cycle.
Because the injection method, formulas, and chemicals to be used are determined in the field,
the operator procedures for adding chemicals are determined locally. See the reference manual for
further information on the optional supply injector, liquid supply injection, and formulas.
Select a formula.
RUN FORMULA
00 OR OK POWER OFF
RUN FORMULA
DOES NOT EXIST
Start the cycle.
When the operator signal is sounding (door closed and formula selected), press
the Start button (1).
Respond to the end of cycle.
WAITING TO UNLOAD
U
xxxxxxxx
TERMINATE TO ESCAPE
1
DANGER: Entangle and Sever Hazards
L
Contact with goods being processed can cause the goods to wrap around your
body or limbs and dismember you. The goods are normally isolated by the locked
cylinder door.
Do not attempt to open the door or reach into the cylinder until the cylinder is
stopped.
1
WARNING: Scald Hazards
D
Contact with hot bath liquor can scald you. Bath liquor can pour from the door or
spray out of ports on the cylinder.
Do not open the cylinder door with water in the cylinder.
Chemical supplies may be added manually or automatically,
The available formulas are listed in the Run Formula menu.
Scroll through the 30 available formulas by pressing the Select Program
button (Q) or the Scroll button (k).
Appears if a non-existent formula is selected.
The cycle is completed.
Press the Terminate Program button (o) to stop the cylinder motion
indicated by the top line and complete the cycle. "TUMBLING" delays the
operator signal for two minutes.
MSOUJMNOAE/9433AV (2 / 3)
5