RECOVERY: Request authorized service.
RECOVERY: Request authorized service.
RECOVERY: Request authorized service to check connections from the ribbon cable to the
processor board and A/D board.
RECOVERY: Request authorized service to check for proper drainage. The message clears when
the level is low enough to begin a new operation.
RECOVERY: Request authorized service to check the cooldown system. The message clears
when cooldown temperature is reached.
RECOVERY: Request authorized service to check the water supply system. The message clears
when the machine fills.
RECOVERY: Request authorized service to check the steam system. The message clears when
the temperature is reached.
A level was still made before or during extract.
The resistance of the temperature probe was less than 2K Ohms or more
than 35K Ohms.
The A/D board did not respond to the microprocessor.
The configured drain time was exceeded.
The configured cooldown time was exceeded.
The configured fill time was exceeded.
The configured time to reach desired steam temperature was exceeded.