Battery selection and
management
This section refers exclusively to 12 V rechargeable batteries.
The batteries you select will depend on whether your
installation is a solar or a battery-only installation. For both
types of installation, the selector switch position you use most
frequently will be a factor. Refer to
explanation of the function of the selector switch.
Battery selection for a battery-only
installation
As a guide, the ampere hour (Ah) rating of the 12 V
rechargeable batteries required is shown below. This table is
based on a seven day operating period between battery
charging. Although operating time can exceed seven days, this
is likely to cause battery damage and will necessitate frequent
replacement of the battery. For best system reliability and long
term battery life, the preferred battery and charging regime is
to use a 12 V rechargeable battery and to recharge it when it is
half discharged.
Selector switch position
or
WARNING!
12 V rechargeable batteries must be used.
Battery selection for a solar
installation
The battery and solar panels must be selected carefully to suit
the energizer's electrical current consumption. As well as the
position of the selector switch position, the battery and solar
panels you choose will depend on the amount of sunshine at
the location of the installation.
As a guide, the minimum amp hour (Ah) rating of the 12 V
rechargeable battery required is shown below. This table shows
the battery requirements for up to seven days of operation with
Operation
for an
Recommended batteries
6 J models
12 J models
450 Ah
700 Ah
575 Ah
900 Ah
575 Ah
900 Ah
370 Ah
600 Ah
700 Ah
1100 Ah
little or no sunlight. It takes into account the variety of solar
panel and regulator types that could be used in a solar
installation.
Selector
Current required
switch
(approximately)
position
6 J models 12 J models
410 mA
700 mA
410 mA
700 mA (day)
(day)
1100 mA
650 mA
(night)
(night)
900 mA
530 mA (24
(24 hour
hour
average)
average)
650 mA
1100 mA (day)
(day)
700 mA (night)
410 mA
900 mA
(night)
(24 hour
530 mA (24
average)
hour
average)
580 mA
or
330 mA
650 mA
1100 mA
WARNING!
12 V rechargeable batteries must be used.
Battery management
WARNING!
Batteries contain harmful chemicals and when
used incorrectly, may cause injury. Observe the guidelines for
battery care, maintenance and safety in this manual and in
the documentation supplied with your battery.
Battery charging
WARNING!
- Do not attempt to recharge a non-rechargeable battery.
- When recharging a battery, ensure that there is adequate
ventilation to allow gases to disperse.
Regular recharging of the battery is essential. Use a suitable
safety approved battery charger and refer to the battery
manufacturer's recommendations.
1
Attach the positive (+) battery charger lead to the positive
terminal of the battery, and the negative (–) battery
charger lead to the negative terminal on the battery.
Minimum battery
capacity (80%
discharge)
6 J models 12 J models
110 Ah
190 Ah
140 Ah
240 Ah
140 Ah
240 Ah
85 Ah
150 Ah
170 Ah
290 Ah
11