Technical data
The information applies at an ambient temperature of 25 °C
Electrical values
Operating voltage
Max. input voltage
Voltage range
Shut-off threshold of op-
tional consumer output
(deep discharge protection)
Reactivation
Perm. ambient temperature
range
Perm. storage temperature
range
Own consumption
Currents
Max. module current
Max. output current
Optional consumer output
Battery capacity
All manuals and user guides at all-guides.com
12 V
47 V
8 – 15 V
11 – 11.5 V
12.5 V
-25 °C – +50 °C
-35 °C – +80 °C
3 mA
3 A (approx. 45 Wp)
3 A
max. 3 A switched
30 – 75 Ah
Charge voltages
Post-charging phase
Trickle charge phase
Main charging phase
changeover voltage
Maximum charge voltage
Temperature compensation
Mechanical values
Protection class:
Assembly
Weight
Connecting terminals
Dimensions L x W x H:
Maximum humidity
(non-condensing)
14.4 V
13.7 V
12.5 V
15.6 V
-24 mV / K
IP 32
Wall mounting
160 g
6 mm² (fine-wire)
10 mm² (single-wire)
146 x 90 x 33 mm
95 %
21