Technical Data
Power supply
AC voltage 230 V / 50 Hz, single-phase
Range approx. 180 V – 250 V / 50 – 60 Hz
Output current (charging current battery II)
Charging current max. 16 A, arithmetic mean value, electroni-
cally controlled according to the IUoU charging reference line
Output current (charging current battery I)
From a battery voltage of 14.1 V in battery II, it is switched
in parallel with battery I. Equalizing current depending on the
charging status of battery I (starter battery). If the voltage of
battery II drops below 13.2 V, the parallel switching is auto-
matically stopped.
Output voltage
DC voltage 12 V
Charging process
Automatic
Automatic switching (main charging process)
OFF at a battery voltage of 14.4 V, charging current < 14,5 A.
Automatic switching (afterl oading phase)
10 hours constant 14.4 V for gel batteries / AGM
4 hours constant 14.4 V for liquid electrolyte batteries
Automatic switching (trickle charging)
Trickle charging constant 13.8 V
Temperature-dependent control (optional)
The values of the automatic switching device refer to a battery
temperature of 20 °C. If a temperature sensor is used with the
battery II, these values will vary in accordance with the battery
temperature.
High temperature
–> reduction of the threshold values.
Lower temperature –> higher threshold values.
Application
Parallel mode, general charging mode.
Temperature
Ambient temperature from -25 °C to +35 °C.
During operation, the casing may heat up to around 75 °C.
Cooling
By convection
Configuration
In accordance with the VDE provisions and the device
safety law
Use
To charge the batteries with 12 V rated voltage and a capacity
of 50 – 160 Ah.
Dimensions / weight
Casing
Aluminum painted, ventilated
Length
220 mm
Width
210 mm
Height
90 mm
Weight
1.3 kg
21