Télécharger Imprimer la page

Function Display / Troubleshooting; Maintenance; Technical Data - Truma SDC 10 Instructions De Montage

Masquer les pouces Voir aussi pour SDC 10:

Publicité

Les langues disponibles

Les langues disponibles

Function display / troubleshooting

LED H1 (H2) shows the status of battery 1 (battery 2).
Display
Cause / rectification
LED flashes in
Check connections from the device to
longer intervals
the battery and solar module, ensure
that they are connected to the right
terminals.
Test the fuse, solar module and the
battery.
LED flashes
Battery is fully charged.
LED shines.
The battery is being charged.
LED flashes in
The battery is not being charged.
short intervals
If necessary, replace faulty battery.
LED does not shine Battery not connected or over-voltage
If this does not solve the problem, please contact the Truma
Service.

Maintenance

The power supply must always be disconnected before
performing any maintenance work. For example cover
the solar module with a cardboard box.
Clean the device with a dry and lint-free cloth.
22
All manuals and user guides at all-guides.com

Technical data

* Double the values of the 12 V – to work out the 24 V values.
Electrical values
Operating voltage
Automatic recognition
max. input voltage
Voltage range *
Allowed ambient tempera-
ture range
Allowed storage temperature
range
Self-consumption
PWM frequency, settable
Currents
max. module current
constant at 25 °C
max. output current
constant at 25 °C
Battery capacity
12 V
24 V
30 V
50 V
8 – 15 V
-35 °C – +55 °C
-35 °C – +80 °C
4 mA at night
10 mA during charging
25 Hz, 50 Hz, 100 Hz
SDC 10
SDC 20
10 A
20 A
(approx.
(approx.
150 Wp)
300 Wp)
10 A
20 A
50 – 100 Ah
50 – 200 Ah

Publicité

loading

Ce manuel est également adapté pour:

Sdc 20