1. General information:
Technical data
Please read both the user manual and the general manual which were delivered with the equipment.
This model is for burning logs, with an additional manually installed feed to take pellets, to continue operation when
logs cannot be supplied.
The pellet stove is composed of a cast iron burner and a wall hopper assembled as shown in this document.
It operates naturally (there is no smoke extractor) and must be lit manually whether using logs or pellets.
There are two methods of operation using pellets.
Fixed output rate chosen by the user
Regulation of room temperature between a minimum and maximum output rate, without extinction or re-
ignition, using the room temperature sensor supplied with the stove, or by connecting an external thermostat.
The rules to follow for its installation are as for a wood stove, including those for the flue and ventilation. (See the
general installation instructions).
Non-continuous use in compliance with standard EN 13240:
Normal Output
Output
Percentage CO2
Green Flame Class
Index and energy efficiency class
dust concentration at 13% O
Emitted
T° smoke
Recommended fuel
Smoke mass debit
Floor protection
The stove must not be placed on flooring made of flammable material or which might be degraded by
heat. If necessary, place the stove centrally on a square concrete slab 100 x 100 cm, 45 mm thick, covered
on its upper surface with a reflective steel plate or reflective ceramic tiles.
Minimum distance from adjacent flammable material: On each side 80 cm
Combustion over a long period
Other inflammable material
Heat output (max / min) and hourly consumption
rate
XD, on 17/02/2020
ARATOS Plug-in
Installation and user guide
2
stove
dual
7 kW
75 %
0.09 %
100 / A
40 mg/Nm
3
356 °C
25 cm diameter wood / logs
Maximum possible length (horizontally): 40 cm
6.6 g/s
8 h
Wood pellets
6,0 kW- 1,6 kg/h / 3.5 kW- 0,80 kg/h
Page 3 sur
model P649000