a junction (B1) which is to be connected with a flexible pipe (not furnished)for the external air intake. The connection pipe must be flat with
a minimum diameter of (B1
with the outside it must be endowed with a special windbreak.)

6. ALLOWED / NOT ALLOWED FUELS

Allowed fuels are logs. Use exclusively dry logs (max. content of water 20%). Maximum 3 logs should be loaded. The pieces of wood
should have a length of ca. 20-30 cm and a maximum circumference of 30-35 cm.
Compressed not worked-out wood briquettes must be used carefully to avoid overheating that may damage the device, since
these have a very high calorific value.
The wood used as fuel must have a humidity content lower than the 20% and must be stored in a dry place. Humid wood tends to burn
less easily, since it is necessary a greater quantity of energy to let the existing water evaporate. Moreover, humid content involves
the disadvantage that, when temperature decreases, the water condensates earlier in the hearth and therefore in the stack causing a
remarkable deposit of soot with following possible risk of fire of the same.
Fresh wood contains about 60% of H
It is necessary to place this wood in a dry and ventilated place (for example under a roofing) for at least two years before using it.
Besides others, it is not possible to burn: carbon, cuttings, waste of bark and panels, humid wood or wood treated with paints,
plastic materials; in this case, the warranty on the device becomes void.
Paper and cardboard must be used only to light the fire.
The combustion of waste is FORBIDDEN and would even damage the appliance and the flue, causing health damages and claims by
the neighborhood owing to the bad smell. The wood is not a fuel which allows a continuous operation of the appliance, as consequence
the heating all over the night is not possible.
Variety
Beech
Oak
Elm
Poplar
Larch*
Spruce*
Scots pine *
ATTENTION : the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly damages the cast iron parts
(cleavage) of the product.

7. LIGHTING

ATTENTION: never light for any reason if the installation is not completely full of water in order to avoid a serious damage of
the whole structure. IABSOLUTELY DO NOT LIGHT THE FIRE IN THE THERMO-FIREPLACE IN THE TOTAL OR PARTIAL
ABSENCE OF WATER (NOT EVEN FOR CHECKING), AS IT COULD BE IRREMEDIABLY RUINED. IN SUCH CASE THE
WARRANTY ON THE APPLIANCE IS VOIDED.
Before installing the facing and lighting the thermo-fireplace, it must be loaded and the system filled from the open expansion tank by
means of the natural fall of the water (see chapter. SYSTEM CONNECTION AND FILLING).
After ensuring that at least one radiator is always open, open the door and load a small quantity of wood.
To light the fire, it is suggested to use small wood pieces together with paper or other traded lighting means. It is FORBIDDEN to use
any liquid substance as for ex. alcohol, gasoline, oil and similar. Never switch on the device when there are combustible gases
in the room.
The openings for air (primary and secondary) must be opened together (you must open the eventual Ignition control, and butterfly valve
placed on the pipe of smokes exhaust). When the wood starts burning, you may load other fuels and adjust the air for combustion
according to the instructions on paragraph TECHNICAL DESCRIPTION.
Please always be present during this phase. Never overload the appliance (see the technical table - max. quantity of fuel that can be
loaded / hourly consumption). Too much fuel and too much air for combustion can cause overheating and therefore damage the
same.
After the first ignition you can smell bad odours (owing to the drying of the glue used in the garnitures or of the paint) which disappear after
22
Picture 14 at page
58), a maximum length of 4 m and with no more than 3 bends. If there is a direct connection
O, therefore it is not suitable to be burnt.
2
*
RESINOUS WOOD NOT SUITABLE FOR THE BURNING
TERMOCAMINO WF25 DSA - WF25X DSA - WF PLUS DSA
Kg/mc
750
900
640
470
660
450
550
kWh/kg
20%
moistness
4,0
4,2
4,1
4,1
4,4
4,5
4,4
6095102 - IT-EN-DE-FR

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wf25x dsaWf plus dsa

Table des Matières