  • Page 1 Dok. Nr: M6490-ETL V: 1.0 2022-03-29 Installation Instructions / Instructions d’installation Centerlift 6490 WWW: Centerlift 6490...
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS / PRESCRIPTIONS DE SÉCURITÉ IMPORTANTES EN When using an electrical furnishing, basic precautions should always be followed, including the following: Read all instructions before using the CENTERLIFT. DANGER - To reduce the risk of electric shock: 1. Always unplug this furnishing from the electrical outlet before cleaning. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1.
  • Page 3 Technical data / Données techniques EN Dhank you for choosing to install a product from Granberg! In order for the product to work safely and securely, it is extremely essential that the installation instructions be followed. The installer should read and understand all the installation instructions before installation begins.
  • Page 4 Planning / Planification EN Very Important! Check floor stability before installation. Maximum load on lifting unit is 440 lb (200kg) and dead load up to 220 lb (100kg). Ensure that the floor can withstand the concentrated load that occurs under motor units. Make sure that the motor units can be fixed to the floor and that the structure is not porous.
  • Page 5 Electricity and Water / Électricité et eau (mm) The lifting unit requires two power outlets and consumes a maximum of 10A (5A+5A). L'unité de levage nécessite deux prises de courant et consomme un maximum de 10 A (5 A+5 A). (mm) 43.5”...
  • Page 6 Accessories / Accessoires ä t T I T : 1 : 760-0x0-01 + 6253-0x0-01 6250-001 6253-0x0-01 6,3x13mm M5x10 DWG NO. 5x16 REVISION Granberg Interior AB Tel. +46(0)11197750 Fax. +46(0)11127676 info@granberg.se TITLE: Systemskruv 5x16 www.granberg.se Drawn Joel FINISH: MATERIAL: 2014-11-26 Checked...
  • Page 7 20 mm 10x M8 x 16mm 10x BR M8 Place the motor units upside down on a flat surface on the floor and screw on the frame. The back should be in line with the rear edge of the motor units. Placez les unités motrices à...
  • Page 8 16 mm 4x BR M8 4x M8 x 16mm Screw on the beam between the motor units Vissez la poutre entre les units motrices CL6490...
  • Page 9 6x M8 x 60mm 6x Mutter M8 Screw the support onto the wheelchair accessible side. Vissez le support sur le côté accessible aux fauteuils roulants. CL6490...
  • Page 10 10 mm 16 mm 4x - M6 x 10mm Front view of lifting unit. Screw the control panel onto the lower aluminium beam. Vue avant de l'unité de levage. Vissez le panneau de commande sur la poutre inférieure en aluminium. CL6490...
  • Page 11 WARNING – Ensure both power supply cords are connected before use AVERTISSEMENT – Avant utilisation, assurez-vous que les deux cordons d'alimentation sont branchés Connect all cables as below Connectez tous les câbles comme ci-dessous Motor left 1 Moteur gauche 1 Motor left 2 Moteur gauche 2 Motor right 1...
  • Page 12 CL6490...
  • Page 13 Position the unit and screw to the floor. There are two mounting holes in each motor unit that must be used. Use fasteners designed for the floor structure in question. Positionnez l'unité et vissez au sol. Il y a deux trous de montage dans chaque unité motrice qui doivent être utilisés. Utilisez des fixations conçues pour la structure du sol en question.
  • Page 14 16 mm 4 x 16 mm Mount the buttons in the wood frontages and screw in the wood screw that keeps the fronts in place. Montez les boutons dans les façades en bois et vissez la vis à bois qui maintient les façades en place. 0.118”...
  • Page 15 16 mm 4 x 16 mm 4.96” (126mm) 14.56” (370mm) CL6490...
  • Page 16 16 mm 14x - 4 x 16 mm CL6490...
  • Page 17 16 mm 3 mm 14x - 4 x 16 mm CL6490...
  • Page 18 4x M5x20 CL6490...
  • Page 19 8x - M5 x 5 mm Lower the lift to the bottom and mount cover plates onto the motor units. Abaissez l'élévateur vers le bas et montez les plaques de recouvrement sur les unités motrices. CL6490...
  • Page 20 6,3x13 Remove the drawers from the cupboards and fit the front hanger brackets loosely so at a later stage they can be adjusted vertically. DWG NO. 5x16 REVISION Granberg Interior AB Tel. +46(0)11197750 Fax. +46(0)11127676 info@granberg.se TITLE: Systemskruv 5x16 www.granberg.se...
  • Page 21 Fit the rear hanger brackets loosely that they can be adjusted horizontally. Please note that only one hanger bracket is used at the rear when the cabinets are mounted directly against the sides. DWG NO. 5x16 REVISION Granberg Interior AB Tel. +46(0)11197750 Fax. +46(0)11127676 info@granberg.se TITLE: Systemskruv 5x16 www.granberg.se...
  • Page 22 Hanging up suspended cabinets. The cabinets are prepared with drawers, fittings and proximity plate. The drawers can be removed to facilitate assembly. The cabinets are lifted in under and hanged on the profile at the front, the rear fitting is pushed into the profile and is left hanging.
  • Page 23 CL6490...
  • Page 24 Hang up the remaining cabinets, with the middle cabinet last. Accrochez les armoires restantes, avec l'armoire du milieu en dernier. CL6490...
  • Page 25 M5x10 Screw the lock plates onto all hanger brackets front and back. Vissez les plaques de verrouillage sur tous les supports de suspension avant et arrière. CL6490...
  • Page 26 Lift the front of the drawer units until they stop, lock with 3x system screws for each plate into the sides of the cabi- net. Then lift the back and lock with 3x system screws in the round holes. 5x16 DWG NO. REVISION Granberg Interior AB Tel. +46(0)11197750 Fax. +46(0)11127676 info@granberg.se TITLE: Systemskruv 5x16 www.granberg.se...
  • Page 27 The hanging drawer units are fitted with active proximity plates. Connect the cables from the proximity plates to the connection boxes as below. Fix the cables with cable tie mounts as illustrated. Les unités de tiroir suspendues sont équipées de plaques de proximité actives. Connectez les câbles des plaques de proximité...
  • Page 28 16 mm 4x - 4 x 16 mm Screw the front finisher onto the front edge of the aluminium profile. Vissez la finition avant sur le bord avant du profilé en aluminium. CL6490...
  • Page 29 The worktop is mounted with double-sided adhesive tape or glue on top of the entire frame. Le plan de travail est monté avec du ruban adhésif double face ou de la colle sur l'ensemble du cadre. CL6490...
  • Page 30: Functional Tests

    Functional tests Complete functional tests should be carried out after installation: Ensure both power supply cords are connected before use! Test run the lift unit up and down all the way to each end position. Make sure that the lift runs freely without obstacles, risk of pinching and noise.
  • Page 31 Before you use the device - Read the users manual Only authorized persons may use the this product! Authorization means obligation to read and follow the instructions. It is very important that you read and understands the users manual before you use the device. The user manual is attached as a separate booklet.
  • Page 34 Granberg Interior AB Box 6112 600 06, Norrköping Tel: 011-19 77 50 E-mail: info@granberg.se Internet: www.granberg.se...