Extension Cords

Use a proper extension cord . ONLY use cords
listed by underwriters Laboratories (UL) .
Other extension cords can cause a drop in
line voltage, resulting in a loss of power and
overheating of tool .
For this tool an AWG (American Wire Gauge)
size of a least 14-gauge is recommended for an
extension cord of 25-ft . or less in length . Use
12-gauge for an extension cord of 50-ft .
Extension cords 100-ft . or longer are not
recommended . Remember, a smaller wire
gauge size has greater capacity than a larger
number (14-gauge wire has more capacity than
16-gauge wire; 12-gauge wire has more
capacity than 14-gauge) . When in doubt use the
smaller number .
Minimum gauge for extension cords
Volts
Total length of cord in feet
120V
25
50
Ampere Rating
More than/
Not more
than
0-6
18
6-10
18
10-12
16
12-16
14
SECURING EXTENSION CORD
8
Important Safety Information
100
150
16
16
14
16
14
12
16
14
12
12
Not recommended
CAUTION: Keep the extension cord clear
of the work area . Position the cord so that it
will not get caught on bushes, hedges, tree
trunks, lawnmowers or other obstructions
while you are working with the pole saw .
WARNING: Check extension cords before
each use . If damaged replace immediately .
Never use tool with a damaged cord since
touching the damaged area could cause
electrical shock, resulting in serious injury .

Residual Risks

WARNING: Even when the unit is used
as prescribed it is not possible to eliminate all
residual risk factors . The following hazards may
arise in connection with the unit's construction
and design:
Damage to lungs if an effective dust mask
is not worn .
Damage to hearing if effective hearing
protection is not worn .
Health defects resulting from vibration
emission if the unit is being used over long
periods of time or not adequately managed
and properly maintained .
WARNING: This unit produces an
electromagnetic field during operation . This
field may, under some circumstances, interfere
with active or passive medical implants . To
reduce the risk of serious or fatal injury, we
recommend persons with medical implants to
consult their physician and the medical implant
manufacturer before operating this unit .
WARNING: Inspect unit before each
use . Replace damaged parts . Make sure all
fasteners are in place and secure . Replace
parts that are cracked, chipped, or damaged in
any way . Make sure the cutting attachment is
properly installed and securely fastened .
WARNING: Do not operate the unit inside a
closed environment, such as a room or building .
Pole Saw Model PS750-091