5 Configuration of the Dante Network

The ETS­630DT is set up in the Dante network
by means of the program "Dante Controller",
available as a free download on the website of
the company Audinate. The settings made via
the program will be saved in the correspond­
ing transmitters and receivers of the Dante
network so that the program is only required
for network configuration but not for normal
operation. The following system requirements
apply to the computer on which the program
"Dante Controller" is to be executed:
Component
Minimum requirements
Processor
1 GHz
RAM
512 Mbytes
Standard Ethernet interface
Network
(100 Mbits /s or Gigabit) or
wireless LAN (WiFi) interface
Windows 7 (SP1 or higher), 8.1 or 10
Note: Both UTF-8 and Unicode will be supported,
except for host names and names of units; the
DNS standard will not support Unicode for them.
Operating system
Mac OS (X) 10.11.6, 10.12.6 , 10.13.6 or 10.14
Note: Intel architecture only; PPC architecture will
not be supported.
Windows is a registered trademark of Microsoft Corporation
in the USA and other countries.
Mac OS is a registered trademark of Apple Inc. in the USA
and other countries.
5.1 Installing the "Dante Controller"
To install the program from the Audinate web­
site:
1) Call up the following Internet address:
https://www.audinate.com/products/
software/dante­controller
2) Select the operating system.
3) Click the button with the version of the
Dante controller.
4) Log in or create an account.
5) Download the software.
6) Install the software.
5.2 Configuration of the unit with the
Dante Controller
1) Start the Dante Controller.
2) Wait for the ETS­630DT and the unit to
which it is to be connected to appear in the
matrix. The ETS­630DT will be listed under
"Dante Receivers".
Note: If a unit fails to appear, the reason may be that
– the corresponding unit has not been switched on
– the unit is in a different subnet
– the unit is not able to synchronize with the other Dante
units.
However, if one of the two last­mentioned reasons ap­
plies, the Dante unit should at least appear under the tab
"Device Info" or "Clock Status" in the network view. A
fast solution of this problem may be to switch the unit off
and on or to disconnect and re­establish the connection to
the network switch. For further information please refer to
the user manual of the Dante Controller from Audinate.
ELECTRONICS FOR SPECIALISTS
3) In the menu bar of the Dante Controller,
select "Device / Device View" or use the
shortcut Ctrl+D. The Device View window
will open.
4) Select the ETS­630DT in the bar of the drop­
down menu appearing beneath the menu
bar.
5) The third bar can be used to indicate infor­
mation on the unit and to make settings.
Select the tab "Device Config" (
6) In the field "Rename Device", the name
used for the unit in the Dante network can
be changed (e. g. to a specific name referring
to the place of installation). Click "Apply" to
confirm the change.
7) Adjust the "Sample Rate" to the desired
connection partner or set a different com­
mon sample rate for both units, if required.
Fig. 2 Device View of ETS-630DT
8) Use the tab "Network Config" to change
the network settings for the Dante interface
of ETS­630DT, if required.
5.3 Routing with the Dante Controller
To assign the input signals and output signals
of the corresponding units:
1) Under "Routing" in the window "Network
View", click
desired unit under "Dante Transmitters" and
the channels of the desired connection part­
ner under "Dante Receivers" (
2) Navigate from the column of the Dante
transmit channel to the line of the desired
Dante receive channel and click the field at
the intersection point.
3) Wait for the field to show a green circle with
a white check mark ✔.
Repeat the steps for additional connections.
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
fig. 2).
to open the channels of the
 fig. 3).
ELECTRONICS
Fig. 3 Routing from ECM-300DT to ETS-630DT
An English user guide for the Dante Control­
ler is available for download on the Audinate
website:
https://www.audinate.com/resources/
technical­documentation
6 Specifications
Amplifier power: . . . . 30 W
Amplifier class: . . . . . . D
Frequency range: . . . . 120 – 18000 Hz
Speakers: . . . . . . . . . . 6 × 7.6 full­range
speakers (3")
Radiation angle
horizontal: . . . . . . . 120°
vertical: . . . . . . . . . 40°
Max. SPL: . . . . . . . . . . 110 dB
Dante channels
Receiver: . . . . . . . . 1
Resolution: . . . . . . . 16 / 24 / 32 bit
Sampling rate: . . . . 44.1 – 96 kHz
Data interface: . . . . Ethernet, RJ45 jack
Power supply: . . . . . . . Power over Ethernet
IEEE 802.3at "PoE+"
Dimensions: . . . . . . . . 95 × 610 × 120 mm
(W × H × D)
Weight: . . . . . . . . . . . 5.57 kg
Subject to technical modification.