SERVICE
Change of water or water-based solvent:
Pull the suction hose (item 1) out of the fresh water container (item 2) under the unit and refill it with fresh water.
Put the container back under the unit and insert the suction hose all the way down.
Empty the left-hand container for return water (item 3) under the unit into a suitable waste drum for hazardous waste, or into a
suitable unit where the return water can be separated from the paint residuals by using the "Flocculation technology". Such units
are the DRESTER Gun Cleaner units 1000, 950, 1050, 9000-TT, 1200 and 2000-TT.
Put the container back under the machine and insert the drain hose from the cleaning box (item 4) into the container.
Change of solvent:
Pull the suction hose (item 1) out of the solvent container (item 2) under the unit and replace it with a container containing clean
solvent ("Permitted solvent" above), then insert the suction hose all the way down.
Empty the container for return solvent (item 3) into a suitable waste drum for hazardous waste, or into a solvent recycler for reuse.
Other:
Replace the brush in the cleaning box when it has been worn out, or overly contaminated.
4
1
3
2
INSTR: 15324
REV: ECO-10003
2014-11-06 / TB
GODK:
SID: 3 / 24