OPERATION

CURING WITH THE MACHINE

CAUTION: Ultraviolet (UV) exposure
may cause eye damage. Do not operate
without coverings. Do not look into UV
source. Wear UV eye protection.
When the Eco--UVS floor coating has relaxed for
a minimum of 15 minutes, push the machine to
the area of the floor that you are going to cure.
Start on an end where you can have have the
electrical cord trail behind you without it dragging
on any of the uncured floor. It is helpful if an
assistant holds the cord until enough of the floor is
cured to allow the cord to drag behind.
Begin curing the floor by pushing the
machine slowly at a rate of about 305 mm
(12 in) every 4 seconds. If the floor feels tacky
on your shoes after the machine has just passed
over it, you are pushing it at a rate that is too fast.
Overlap each pass by about 50 mm (2 in). Push
the machine in a straight line as possible to make
it easier to make the next pass. It is better to
overlap too much than to to miss an area and not
have it cured.
NOTE: If the lighting conditions are too poor to
see where the last pass ended, it may be helpful
to use a laser level as a guide.
6
Home

CHANGING LIGHT BULBS

WARNING: Hazardous voltage. Unplug
power cord before servicing machine.
Unplug the machine, then allow the bulbs to cool
before replacing them. Clean the new bulb with
the Isopropylalcohol towel provided with the
replacement bulb before inserting it into the
machine. Do not touch the bulb with your hands
as that will shorten the life of the bulb.
FOR SAFETY: When servicing machine, allow
bulbs to cool before replacing.
Find... Go To..
SunFlash 331130 (7- -04)