Storage control of Lithium battery
designed for charging or discharging of batteries of specific original state. They are classified
by types: 3.75V Lilo, 3.85V LiPo and 3.3V LiFe.
The program will begin to discharge if the original state of the battery exceeds the voltage level of
storage.
At this screen, you can set up the current and voltage of the battery pack. Charging and dis-
charging will make the batteries come to the voltage level of "storage" state.
This screen shows the real-time status charging. Press "Batt type/Stop" key once to stop the
charge process.
Discharging of Lithium battery
The value of discharge current on the left cannot exceed 1C, and the value on the right cannot
be under the voltage recommended by the manufacturer to avoid deep discharging. Press "Start/
Enter" for more than 3 seconds to start charging.
This shows the real-time status of discharging, you can press "Batt type/Stop" key to stop dis-
charging.
12
Charging current
Number of cells
Elapsed time
Charging or discharging
Number of cells
current
Elapsed time
www.rcplus.eu
Battery voltage
Supplied capacity
Current battery voltage
Supplied capacity