8.
START-UP
8.1.
Safety instructions
WARNING!
Risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar
with and completely understand the contents of the operating
instructions.
• The safety instructions and "2. Authorized use" must be
observed.
• Only adequately trained personnel may start up the equipment/
device.
Type 7615
Start-up
8.2.
Control diagram
V1
V2
V3
T0
T1
T2
Fig. 5:
Control diagram
V1 = inlet valve
V2 = dosing valve
V3 = discharge valve
The optional control times are saved in the dosing unit software and
cannot be changed.
english
T3
T4
T5
T6
T1
11