BM 2609140484 02-07
Cleaning
To avoid accidents always
!
WARNING
disconnect the tool from
the power supply before cleaning or
performing any maintenance. The tool may
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
If an extension cord is
!
WARNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
PR002 Straight Router Guide*
PR003 Roller Guide
PR004 Offset Base with Trim Guide
†
PR005 Tilt Base
PR006 Underscribe Attachment
PR007 Side-Handle Subbase with Dust
Extraction Hood
PR008 Base Cover
PR009 Round Subbase for RA-Series
Templet Guide
2/28/07
9:38 AM
Accessories
†
†
†
†
Page 21
not attempt to clean by inserting pointed
objects through openings.
Certain cleaning agents
!
CAUTION
and
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
50
3-6
18
16
6-8
18
16
8-10
18
16
10-12
16
16
12-16
14
12
PR010 Round Subbase for Threaded
Templet Guide
83038 Hinge Templet Kit
Router Bits
†
Case*
Vacuum Hoses
Vacuum Hose Adapter
*Included with PR20EVSK
†
Included with PR20EVSNK
-21-
solvents
damage
Wire Sizes in mm
Cord Length in Meters
100 150
15
30
60
120
16
14
0.75 0.75 1.5
2.5
14
12
0.75 1.0 2.5
4.0
14
12
0.75 1.0 2.5
4.0
14
12
1.0 2.5 4.0
—
—
—
—
—
—
—
2