TECHNICAL DATA MODEL: PHV
TECHNICAL DATA
Current
Power
Consumption
Condenser
Maximum Pressure
Hydraulic Arm
Hydraulic arm exit time
Hydraulic arm entry time
Compression
Traction
Max. Length of gate leaf
Temperature Range
Thermic Protection
Weight
3 of 10
Dimensions
PHV
240
360
230V 50HZ
276 W
1,3 A
16 uf
50 bar
242 mm
362 mm
28 sec.
40 sec.
23 sec.
34 sec.
0 to 7793 N (795Kg)
0 to 6252 N (638Kg)
4 m
6 m
-15 to 80° C
100° C
11 Kg
12 Kg
Ed1. 14/12/09 (English)
PHV240
985 mm
A
915 mm
B
C
673 mm
242 mm
D
FEATURES
HYDRAULIC LOCK OUT PUT
BLOCK OPEN & CLOSE
BLOCK CLOSE
BLOCK OPEN
REVERSABLE IN BOTH DIRECTIONS
ANTI-WIND REGULATION
BUFFER STOP CLOSE
SB = WITHOUT BLOCK
BAC = BLOCK, OPEN, CLOSE
PHV360
1225 mm
1155 mm
793 mm
362mm
PHV
SB