ADDITIONAL PROGRAMMING
Reset Master Code
Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the
frequency and encryption type. After resetting the Master Code, the keypad will not operate any previously
programmed operators until they are reprogrammed. To reset the Master Code to the factory default (888888):
1. Unlock and remove the faceplate.
2. Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the
Master Code has been reset.
Reset Keypad
Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and
encryption settings. All settings will be set to factory default. After resetting, the keypad will not operate the
previously programmed operators until they are reprogrammed. To reset the keypad:
1. Unlock and remove the faceplate.
2. Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release.
3. Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the
keypad has been reset.
Lockout Mode (Default is ON)
If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any
keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs.
Programming Step
1. Enter program mode
2. Set Lockout mode to ON:
3. Exit Program Mode
Programming Step
1. Enter program mode
2. Set Lockout mode to OFF:
3. Exit Program Mode
Constant Pressure Override (CPO)
The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection
system, in order to operate the gate until the external entrapment protection device is realigned or repaired.
Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment
protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and
wireless safety edge sensors. Be sure to repair or replace these devices promptly if they are not working
properly.
CPO is only compatible with LiftMaster 2016 UL 325 Compliant Gate Operators (with burgundy boards) that
require monitored entrapment protection.
To use Constant Pressure Override:
1. Enter a valid 4-digit PIN.
2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A
continuous tone will sound until limit is met and/or # is released.
3. The operator will stop when either the operator reaches a limit or the user releases #.
Keystroke Combination
(Master Code) #
*
02 # 1 #
#
* *
Keystroke Combination
(Master Code) #
*
02 # 0 #
#
* *
5
Indicator
Long tone
Long tone
Keypad backlight will turn off
Indicator
Long tone
Long tone
Keypad backlight will turn off