Universal Remote Control
Read instructions thoroughly BEFORE beginning.
Start with garage door closed. Identify garage door opener type - Smart/
STOP
Learn button or DIP Switch. Smart/Learn button or DIP Switches are
located on motor unit or external receiver.
Refer to owner's manual if necessary.
Proceed with instructions according to your type of garage door opener.
SMART/LEARN BUTTON
1
See Chart A to
determine # of times to
press button and write
in blank on step 5.
2
3
Press program button
until LED lights.
4
1
2
3
KG
KG
Motor Unit
Press and release the
smart/learn button.
5
Select a button to program.
Press button
times
ensuring LED stops flashing
after each press. Code is
accepted when one of the
following occurs:
Click
OR
OR
6
Press program button.
7
Programming complete.
Press selected button
to test. If unit does not
work, return to Step 3.
www.LiftMaster.com
1-800-442-1255
Chamberlain, LiftMaster and Moore-O-Matic are Trademarks of Chamberlain Group. Genie
is a Trademark of Overhead Door Corporation. Overhead Door is a Trademark of Overhead
Door Corporation. Linear is a Trademark of Linear Corporation. Master Mechanic is a
Trademark of TruServ. Sears is a Trademark of Sears & Roebuck. Stanley is a Trademark
of The Stanley Works. Wayne Dalton is a trademark of Wayne Dalton Corporation. Do It is
a trademark of Do It Best Corporation.
114A3492B
MODELS 375LM & 375LMC
CHART A
# of
Brand
Type/Color of
times to
Smart/Learn
press
button
®
1
Linear
Mega-Code
®
2
Chamberlain
*
Orange
®
3
Chamberlain
*
Purple
®
4
Chamberlain
*
Green
®
5
Genie
®
Overhead Door
Intellicode
®
6
Genie
®
Overhead Door
Intellicode
®
7
Stanley
Secure Code
®
9
Wayne Dalton
Rolling Code
®
11
Chamberlain
*
9 Position
*NOTE: LiftMaster, Do-It, Master Mechanic, Raynor, True Value and Sears Craftsman are compatible
with Chamberlain technology.
SMART/LEARN BUTTON
1
2
KG
NOTE: Your opener may
appear different and you
may have to remove the
light lens to access the
learn button.
LED Indicator
Button 1
Program Button
Battery
REMOTE CONTROL BATTERY
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• Do NOT recharge, disassemble, heat above 212°F (100°C) or
incinerate.
Dispose of batteries properly. Replace ONLY with 3V2032 coin
batteries.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:
• ALWAYS keep remote controls out of reach of children. NEVER permit children to
operate, or play with remote control transmitters.
• Activate gate or door ONLY when it can be seen clearly, is properly adjusted and there
are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed. NEVER permit
anyone to cross path of moving gate or door.
Year
# of
Brand
times to
press
button
11
Chamberlain
'97-Current
12
Chamberlain
'97-'05
'05-Current
®
13
Genie
'93-'96
14
Linear Multicode
15
Chamberlain
'95-Current
16
Stanley/Multicode
®
17
Genie
'05-Current
®
18
Linear
'98
Moore-O-Matic
'99
19
Chamberlain
'90-'92
DIP SWITCH
OR
ON
3
KG
DIP Switches
Battery Cover
© 2008, The Chamberlain Group, Inc.
All Rights Reserved
CHART B
Description
Year
®
*
9 Position
'90-'92
®
*
9 Position
Canada
'83-'89
12 Position
'85
®
10 Position
'76
®
8 Position
'83-'89
®
10 Position
'76
9 Position
'85
®
8 Position
'76
®
*
7 Position
'83-'89
Button 2
NOTE:
2 Position DIP Switch:
If programming fails reverse
DIP switches (OFF to ON and
ON to OFF).
**3 Position DIP Switch:
For Chamberlain remotes DO NOT
use the "0" position, use "+" or "-".
If you already have a 3-button
remote, DIP switch #1 must be set to
"-" if the large button is to open the door. It may be
necessary to reprogram original remote controls.
DIP SWITCH
1
See Chart B to
determine # of times to
press button and write
in blank on step 5.
2
3
Motor
Unit
Existing Remote
Clicker Remote
Match DIP switches. Turn
extra switches OFF.**
4
Press program button
until LED lights.
5
Select a button to program.
Press button
times
ensuring LED stops flashing
after each press. Code is
accepted when door
activates.
6
Press program button.
7
Programming complete.
Press selected button
to test. If unit does not
work, return to Step 3.
ON