Installation/Setup
Only qualified staff is allowed to mount, connect and set up the
modules.
Applications:
The compact AS-i E-STOP safety module (AC010S) is used to detect
safety-related switching states. For this purpose a code table is trans-
ferred via the AS-i system with 8 x 4 bits which is evaluated by the
safety monitor (e.g. AC001S ... AC004S).
When operated correctly, the system reaches safety category 4 accord-
ing to EN 954-1.
Attention!
Depending on the safety components used the complete safety
system can also be classified in a lower safety category!
Function and electrical connection:
Please refer to all information in the description of the configuration
software (E7020S) and the installation instructions of the unit. These
documents provide all required instructions concerning installation,
configuration, operation and maintenance of the compact AS-i E-STOP
safety module.
Information on the parameterizable safety functions of the compact
AS-i E-STOP safety module can be found in the chapter "Monitoring
devices" (two positively-driven NC contacts) of the configuration
software manual.
Important note:
The products described herein are designed to be components of
a customized machinery safety-oriented control system. A com-
plete safety-oriented control system may include safety sensors,
evaluators, actuators and signalling components. It is the res-
ponsibility of each company to conduct its own evaluation of the
effectiveness of the safety system. The manufacturer of the com-
pact AS-i E-STOP safety module, his subsidiaries and affiliates are
not in a position to evaluate all of the characteristics of a given
machine or product.