Energi Savr Node
Step-by-step installation instructions
Step 1: Mounting the Energi Savr Node (ESN)
with EcoSystem unit
Note: Mount the ESN with EcoSystem unit in a position where it
can be easily located and accessed if service or troubleshooting
is necessary.
• For indoor use only!
• NEMA, Type 1 enclosure, IP20.
• Remove metal outer panel cover.
• Remove internal plastic line voltage shield.
• Choose panel mounting location so line voltage wiring is at least
6 ft (1.8 m) from audio or electronic equipment and associated
wiring (prevents radio frequency interference).
• Install in accordance with all national and local electrical codes.
• Can be installed in accordance with National Electrical Code
(NEC
) Article 300.22(c) "Other places used for environmental
®
air".
Step 2: Control power wiring
The ESN with EcoSystem unit operates at 120-277 V . Use
the following instructions to wire line voltage to the ESN with
EcoSystem unit .
WARNING! Danger of Shock. May result in serious
injury or death. DO NOT WIRE WHEN LIVE! Switch off
power to all power feeds via circuit breaker or isolator
before wiring or servicing the ESN with EcoSystem unit .
Buttons and LEDs in the unit are used for troubleshooting.
If wiring is exposed when accessing buttons and LEDs, the
unit must be accessed by a certified electrician, following
local codes.
1. Turn power off.
2. Remove metal outer panel cover.
3. Remove internal plastic line voltage shield.
4. Use 14 AWG to 12 AWG (2.5 mm
pending on breaker rating) to feed the control power wiring. The
device draws less than 0.5 A.
5. Wire the line voltage cables to the terminals labeled H (Hot), N
(Neutral) and G (Ground).
6. Reinstall internal plastic line voltage shield.
7. Turn on the circuit breaker or isolator to power up the ESN with
EcoSystem unit. The Power LED on the ESN with EcoSystem
unit will illuminate continuously when properly energized. If the
LED does not light, turn off power, then check the control power
wiring.
8. Turn power off.
Energi Savr Node
with EcoSystem
TM
English
with EcoSystem
TM
®
to 4.0 mm
) conductors (de-
2
2
Installation Guide
®
Español
Français
|
Installation Guide
®
Mechanical Dimensions
All dimensions shown as inches (mm)
9.25
(234.95)
1.66
(42.16)
7.50
(190.50)
Line Voltage Shield
(285.75)
Control Power Wiring
Português
1.31
(33.27)
1.22
(30.99)
3.16
(80.26)
0.88
1.22
(22.35)
(30.99)
1.00
(25.40)
Do not use
knockouts
located in
this area
on either
11.25
side of the
enclosure.
13.25
(336.55)
0.20
(5.16) dia.
Control Power Wiring:
• Two (2) 14 AWG to 12 AWG
(2.5 mm
to 4.0 mm
)
2
2
• Strip length: 3/8 in (8.5 mm)
• Torque: 7 in-lb (0.79 N
Lutron
m)
•
3
|
®